Clinical Imaging Characteristics of the Positron Emission Mammography PEM Flex Solo II.

Lawrence Macdonald1, John Edwards, Thomas Lewellen, James Rogers, Paul Kinahan.   

Abstract

Positron emission mammography (PEM) uses two opposing gamma-ray imagers and limited-angle tomography techniques to image radiotracer distributions within the breast. Due to their smaller size and closer proximity to the source, dedicated PEM cameras can provide better spatial resolution and count sensitivity than whole-body positron emission tomographs. We performed several clinical imaging tests on a commercially available PEM camera, the PEM Flex Solo II. This system is comprised of two opposing 6 cm × 16.4 cm detectors that scan in unison to cover up to a 24 cm × 16.4 cm field of view (FOV). We measured spatial resolution, uniformity, recovery coefficients (RC), and quantification using the system clinical software. Image linearity and coefficient of variation (CV) at the edge of the FOV were also characterized. Anecdotal examples of clinical patient data are presented. Spatial resolution is 2.4 mm FWHM for image planes parallel to the detector faces; background variability is 6%; quantification and RC varied within the FOV; positioning linearity began at ~ 13 mm from the edge of the detector housing; CV increased rapidly at the edge of the FOV due to limited sampling in these image planes.

Entities:  

Year:  2008        PMID: 20502537      PMCID: PMC2875249          DOI: 10.1109/NSSMIC.2008.4774291

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  4 in total

Review 1.  Current and future uses of positron emission tomography in breast cancer imaging.

Authors:  William B Eubank; David A Mankoff
Journal:  Semin Nucl Med       Date:  2004-07       Impact factor: 4.446

2.  Instrumentation for Positron Emission Mammography.

Authors:  Christopher J Thompson
Journal:  PET Clin       Date:  2006-01

3.  Feasibility study for positron emission mammography.

Authors:  C J Thompson; K Murthy; I N Weinberg; F Mako
Journal:  Med Phys       Date:  1994-04       Impact factor: 4.071

Review 4.  Screening for breast cancer.

Authors:  Joann G Elmore; Katrina Armstrong; Constance D Lehman; Suzanne W Fletcher
Journal:  JAMA       Date:  2005-03-09       Impact factor: 56.272

  4 in total
  2 in total

1.  Performance characterization of a new high resolution PET scintillation detector.

Authors:  A Vandenbroucke; A M K Foudray; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2010-09-16       Impact factor: 3.609

Review 2.  Dedicated Breast Gamma Camera Imaging and Breast PET: Current Status and Future Directions.

Authors:  Deepa Narayanan; Wendie A Berg
Journal:  PET Clin       Date:  2018-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.