Literature DB >> 20502493

Validation of continuous particle monitors for personal, indoor, and outdoor exposures.

Lance A Wallace1, Amanda J Wheeler, Jill Kearney, Keith Van Ryswyk, Hongyu You, Ryan H Kulka, Pat E Rasmussen, Jeff R Brook, Xiaohong Xu.   

Abstract

Continuous monitors can be used to supplement traditional filter-based methods of determining personal exposure to air pollutants. They have the advantages of being able to identify nearby sources and detect temporal changes on a time scale of a few minutes. The Windsor Ontario Exposure Assessment Study (WOEAS) adopted an approach of using multiple continuous monitors to measure indoor, outdoor (near-residential) and personal exposures to PM₂.₅, ultrafine particles and black carbon. About 48 adults and households were sampled for five consecutive 24-h periods in summer and winter 2005, and another 48 asthmatic children for five consecutive 24-h periods in summer and winter 2006. This article addresses the laboratory and field validation of these continuous monitors. A companion article (Wheeler et al., 2010) provides similar analyses for the 24-h integrated methods, as well as providing an overview of the objectives and study design. The four continuous monitors were the DustTrak (Model 8520, TSI, St. Paul, MN, USA) and personal DataRAM (pDR) (ThermoScientific, Waltham, MA, USA) for PM₂.₅; the P-Trak (Model 8525, TSI) for ultrafine particles; and the Aethalometer (AE-42, Magee Scientific, Berkeley, CA, USA) for black carbon (BC). All monitors were tested in multiple co-location studies involving as many as 16 monitors of a given type to determine their limits of detection as well as bias and precision. The effect of concentration and electronic drift on bias and precision were determined from both the collocated studies and the full field study. The effect of rapid changes in environmental conditions on switching an instrument from indoor to outdoor sampling was also studied. The use of multiple instruments for outdoor sampling was valuable in identifying occasional poor performance by one instrument and in better determining local contributions to the spatial variation of particulate pollution. Both the DustTrak and pDR were shown to be in reasonable agreement (R² of 90 and 70%, respectively) with the gravimetric PM₂.₅ method. Both instruments had limits of detection of about 5 μg/m³. The DustTrak and pDR had multiplicative biases of about 2.5 and 1.6, respectively, compared with the gravimetric samplers. However, their average bias-corrected precisions were <10%, indicating that a proper correction for bias would bring them into very good agreement with standard methods. Although no standard methods exist to establish the bias of the Aethalometer and P-Trak, the precision was within 20% for the Aethalometer and within 10% for the P-Trak. These findings suggest that all four instruments can supply useful information in environmental studies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20502493     DOI: 10.1038/jes.2010.15

Source DB:  PubMed          Journal:  J Expo Sci Environ Epidemiol        ISSN: 1559-0631            Impact factor:   5.563


  26 in total

1.  Monitoring an outdoor smoking area by means of PM2.5 measurement and vegetal biomonitoring.

Authors:  Alan da Silveira Fleck; Maria Fernanda Hornos Carneiro; Fernando Barbosa; Flavia Valladão Thiesen; Sergio Luis Amantea; Claudia Ramos Rhoden
Journal:  Environ Sci Pollut Res Int       Date:  2015-12-11       Impact factor: 4.223

2.  Kitchen concentrations of fine particulate matter and particle number concentration in households using biomass cookstoves in rural Honduras.

Authors:  Megan L Benka-Coker; Jennifer L Peel; John Volckens; Nicholas Good; Kelsey R Bilsback; Christian L'Orange; Casey Quinn; Bonnie N Young; Sarah Rajkumar; Ander Wilson; Jessica Tryner; Sebastian Africano; Anibal B Osorto; Maggie L Clark
Journal:  Environ Pollut       Date:  2019-12-04       Impact factor: 8.071

3.  One Year Evaluation of Three Low-Cost PM2.5 Monitors.

Authors:  Misti Levy Zamora; Jessica Rice; Kirsten Koehler
Journal:  Atmos Environ (1994)       Date:  2020-05-31       Impact factor: 4.798

4.  Elemental analysis of infant airborne particulate exposures.

Authors:  Chantel D Sloan; Frank X Weber; Rebecca K Bradshaw; Tyler J Philipp; W Bradford Barber; Vanessa L Palmer; Robert J Graul; Steven C Tuttle; Ryan T Chartier; James D Johnston
Journal:  J Expo Sci Environ Epidemiol       Date:  2016-12-21       Impact factor: 5.563

5.  Different relationships between personal exposure and ambient concentration by particle size.

Authors:  Sooyoung Guak; Kiyoung Lee
Journal:  Environ Sci Pollut Res Int       Date:  2018-04-06       Impact factor: 4.223

6.  Evaluation of Diesel Exhaust Continuous Monitors in Controlled Environmental Conditions.

Authors:  Chang Ho Yu; Allison P Patton; Andrew Zhang; Zhi-Hua Tina Fan; Clifford P Weisel; Paul J Lioy
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

7.  Physiological and perceived health effects from daily changes in air pollution and weather among persons with heart failure: a panel study.

Authors:  Mark S Goldberg; Amanda J Wheeler; Richard T Burnett; Nancy E Mayo; Marie-France Valois; James M Brophy; Nadia Giannetti
Journal:  J Expo Sci Environ Epidemiol       Date:  2014-06-18       Impact factor: 5.563

8.  Improved exposure characterization with robotic (PIPER) sampling and association with children's respiratory symptoms, asthma and eczema.

Authors:  Maya Ramagopal; Zuocheng Wang; Kathleen Black; Marta Hernandez; Adam A Stambler; Osiloke H Emoekpere; Gediminas Mainelis; Stuart L Shalat
Journal:  J Expo Sci Environ Epidemiol       Date:  2014-05-07       Impact factor: 5.563

9.  Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

Authors:  Zuocheng Wang; Leonardo Calderón; Allison P Patton; MaryAnn Sorensen Allacci; Jennifer Senick; Richard Wener; Clinton J Andrews; Gediminas Mainelis
Journal:  J Air Waste Manag Assoc       Date:  2016-11       Impact factor: 2.235

10.  Impact of microenvironments and personal activities on personal PM2.5 exposures among asthmatic children.

Authors:  Keith Van Ryswyk; Amanda J Wheeler; Lance Wallace; Jill Kearney; Hongyu You; Ryan Kulka; Xiaohong Xu
Journal:  J Expo Sci Environ Epidemiol       Date:  2013-05-01       Impact factor: 5.563

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.