Literature DB >> 20495203

Mechanical circulatory support in patients of advanced age.

Thorsten Drews1, Alexander Stepanenko, Michael Dandel, Semih Buz, Hans Brendan Lehmkuhl, Roland Hetzer.   

Abstract

AIMS: In recent years, non-pulsatile assist devices have been increasingly used for long-term circulatory support. However, it remains to be established whether pulsatile and non-pulsatile systems can ensure a similarly low rate of complications for extended periods of time in elderly patients. METHODS AND
RESULTS: Of 174 patients implanted between June 1991 and January 2009 [mean age: 65 +/- 3.7 (60-80) years], 64 were on pulsatile (39 Berlin Heart EXCOR, 18 Novacor, 4 LionHeart, and 3 HeartMate I) and 110 on non-pulsatile assist devices (65 Berlin Heart INCOR, 18 DeBakey, 14 HeartMate II, 7 DuraHeart, and 6 Jarvik2000). In the pulsatile group, the mean support time was 157 +/- 343 (1-1836) days, and in the non-pulsatile group 281 +/- 336 (1-1619) days (P < 0.05). The 1-year survival was 15% in the pulsatile group and 36% in the non-pulsatile group, and 2-year survival was 12 and 26%, respectively (P < 0.05). In the pulsatile group, 11 patients (17%) were supported for >6 months, 7 patients (11%) for >1 year, and 3 patients (5%) for >2 years, and 3 patients underwent heart transplantation, 3 were weaned, and 3 still have a device. In the non-pulsatile group, 46 patients (42%) were supported for >6 months, 34 (28%) for >1 year, and 14 (13%) for >2 years, and 17 patients are still on support, 9 underwent transplantation, and 3 were weaned.
CONCLUSION: Although both types of device can be used for extended periods of time, non-pulsatile systems have a significantly higher survival rate in elderly patients. They allow elderly patients additional years of life in their familiar environment.

Entities:  

Mesh:

Year:  2010        PMID: 20495203     DOI: 10.1093/eurjhf/hfq076

Source DB:  PubMed          Journal:  Eur J Heart Fail        ISSN: 1388-9842            Impact factor:   15.534


  3 in total

Review 1.  Mechanical circulatory support for elderly heart failure patients.

Authors:  Craig R Butler; Bodh I Jugdutt
Journal:  Heart Fail Rev       Date:  2012-09       Impact factor: 4.214

2.  Flow field study comparing design iterations of a 50 cc left ventricular assist device.

Authors:  Jason C Nanna; Jennifer A Wivholm; Steven Deutsch; Keefe B Manning
Journal:  ASAIO J       Date:  2011 Sep-Oct       Impact factor: 2.872

3.  Ventricular assist device implantation in the elderly.

Authors:  William Hiesinger; Jack H Boyd; Y Joseph Woo
Journal:  Ann Cardiothorac Surg       Date:  2014-11
  3 in total