Literature DB >> 20494762

Straylight measurements in pseudophakic eyes with natural and dilated pupils: one-year follow-up.

Kim W van Gaalen1, Steven A Koopmans, Johanna M M Hooymans, Nomdo M Jansonius, Aart C Kooijman.   

Abstract

PURPOSE: To compare the amount of straylight in natural pupils and dilated pupils in pseudophakic eyes 6 weeks and 1 year after cataract extraction.
SETTING: Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
METHODS: This study evaluated patients with bilateral age-related cataract who had cataract surgery with implantation of an aspheric Tecnis ZA9003 or spherical Sensar AR40e intraocular lens (IOL). Straylight measurements were performed with a C-Quant straylight meter 6 weeks after surgery (with natural pupils) and 1 year after surgery (with natural and dilated pupils) in a randomly chosen eye. Retroillumination photographs of dilated pupils were taken to document posterior capsule opacification. The main outcome variable for straylight measurements was the logarithmic straylight parameter, log(s).
RESULTS: Twenty-two patients were evaluated. There was a statistically significant decrease in straylight in a natural pupil between 6 weeks (mean 1.44 log[s]) and 1 year (mean 1.30 log[s]) postoperatively (P = .012). The straylight parameter was greater after dilation (mean 1.48 log[s]) than with a natural pupil (1.29 log[s]) at 1 year (P = .012). This difference was greater when more anterior capsule was visible in the pupillary area (P = .031).
CONCLUSIONS: Straylight decreased significantly in the first year after cataract surgery. Furthermore, it increased with increasing pupil size, which was associated with a capsulorhexis smaller than the pupil. This indicates the capsulorhexis should be as large as possible to prevent straylight, especially under low-luminance conditions when the pupil is large. (c) 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20494762     DOI: 10.1016/j.jcrs.2009.12.048

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Comparison of pseudophakic retinal straylight in spherical/aspherical and hydrophobic/hydrophilic intraocular lens.

Authors:  Yong Tang; Hui Song; Jing Chen; Xin Tang
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric, aberration correcting monofocal intraocular lens.

Authors:  Florian T A Kretz; Tamer Tandogan; Ramin Khoramnia; Gerd U Auffarth
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

3.  Combining in vitro test methods for measuring light scatter in intraocular lenses.

Authors:  Marrie van der Mooren; Tom van den Berg; Joris Coppens; Patricia Piers
Journal:  Biomed Opt Express       Date:  2011-02-04       Impact factor: 3.732

4.  Changes in forward light scatter parameters as a function of refractive error in young adults.

Authors:  Manbir Nagra; Mansi Patel; John Barbur
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-07       Impact factor: 3.117

5.  Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens.

Authors:  Ya-Wen Guo; Jun Li; Hui Song; Xin Tang
Journal:  J Ophthalmol       Date:  2014-03-03       Impact factor: 1.909

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.