Literature DB >> 20493321

Use of a CAD/CAM-fabricated glass fiber post and core to restore fractured anterior teeth: A clinical report.

Peng Liu1, Xu-Liang Deng, Xin-Zhi Wang.   

Abstract

Prefabricated glass fiber posts are widely used; however, their shape cannot be changed and they can be unsuitable for severely damaged teeth with wide root canals. This clinical report describes a procedure for restoring a severely damaged anterior tooth with a customized 1-piece glass fiber post and core, fabricated using a CAD/CAM system. This 1-piece glass fiber post and core adapts better to the root canal than a prefabricated glass fiber post, and reduces the cement layer thickness. Furthermore, it does not require the use of a composite resin foundation. Copyright 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20493321     DOI: 10.1016/S0022-3913(10)60071-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

Review 1.  Customized Post and Cores Fabricated with CAD/CAM Technology: A Literature Review.

Authors:  Faisal D Al-Qarni
Journal:  Int J Gen Med       Date:  2022-05-06

2.  In vitro evaluation of the post-space depth reading with an intraoral scanner (IOS) compared to a traditional silicon impression.

Authors:  A Pinto; L Arcuri; P Carosi; R Nardi; A Libonati; L Ottria; V Campanella
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

3.  The effect of time and storage environment on dimensional changes of acrylic resin post patterns.

Authors:  Mahmoud Sabouhi; Saied Nosouhian; Mansour Dakhilalian; Amin Davoudi; Ramin Mehrad
Journal:  Open Dent J       Date:  2015-01-30

4.  CAD/CAM Customized Glass Fiber Post and Core With Digital Intraoral Impression: A Case Report.

Authors:  Antonio Libonati; Virginia Di Taranto; Gianni Gallusi; Edoardo Montemurro; Vincenzo Campanella
Journal:  Clin Cosmet Investig Dent       Date:  2020-02-10

Review 5.  Efficacy of CAD/CAM Glass Fiber Posts for the Restoration of Endodontically Treated Teeth.

Authors:  Maira Alejandra Gutiérrez; Camilo Alejandro Guerrero; Paula Alejandra Baldion
Journal:  Int J Biomater       Date:  2022-01-21

6.  In vitro Results of Scanning Technique on Assessing Cement Thickness and Interfacial Nanoleakage of Luted CAD/CAM-Fabricated Fiber Posts.

Authors:  Sunil Kumar Vaddamanu; Rajesh Vyas; Shashit Shetty Bavabeedu; Suraj Arora; Bhumika Kamal Badiyani; Amit Kumar
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

7.  Finite Element Study of PEEK Materials Applied in Post-Retained Restorations.

Authors:  Hao Yu; Zhihong Feng; Ling Wang; Senay Mihcin; Jianfeng Kang; Shizhu Bai; Yimin Zhao
Journal:  Polymers (Basel)       Date:  2022-08-22       Impact factor: 4.967

8.  Push-Out Bond Strength of Endodontic Posts Cemented to Extracted Teeth: An In-Vitro Evaluation.

Authors:  Syed Rashid Habib; Abdul Sadekh Ansari; Aleshba Saba Khan; Nawaf M Alamro; Meshari A Alzaaqi; Yazeed A Alkhunefer; Abdulaziz A AlHelal; Talal M Alnassar; Abdulaziz S Alqahtani
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.