Reducing modeling error of graphical methods for estimating volume of distribution measurements in PIB-PET study.

Hongbin Guo1, Rosemary A Renaut, Kewei Chen, Eric M Reiman.   

Abstract

Graphical analysis methods are widely used in positron emission tomography quantification because of their simplicity and model independence. But they may, particularly for reversible kinetics, lead to bias in the estimated parameters. The source of the bias is commonly attributed to noise in the data. Assuming a two-tissue compartmental model, we investigate the bias that originates from modeling error. This bias is an intrinsic property of the simplified linear models used for limited scan durations, and it is exaggerated by random noise and numerical quadrature error. Conditions are derived under which Logan's graphical method either over-or under-estimates the distribution volume in the noise-free case. The bias caused by modeling error is quantified analytically. The presented analysis shows that the bias of graphical methods is inversely proportional to the dissociation rate. Furthermore, visual examination of the linearity of the Logan plot is not sufficient for guaranteeing that equilibrium has been reached. A new model which retains the elegant properties of graphical analysis methods is presented, along with a numerical algorithm for its solution. We perform simulations with the fibrillar amyloid beta radioligand [11C] benzothiazole-aniline using published data from the University of Pittsburgh and Rotterdam groups. The results show that the proposed method significantly reduces the bias due to modeling error. Moreover, the results for data acquired over a 70min scan duration are at least as good as those obtained using existing methods for data acquired over a 90min scan duration. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20493196      PMCID: PMC2900488          DOI: 10.1016/j.mbs.2010.05.002

Source DB:  PubMed          Journal:  Math Biosci        ISSN: 0025-5564            Impact factor:   2.144


  19 in total

1.  Effects of statistical noise on graphic analysis of PET neuroreceptor studies.

Authors:  M Slifstein; M Laruelle
Journal:  J Nucl Med       Date:  2000-12       Impact factor: 10.057

Review 2.  Positron emission tomography compartmental models.

Authors:  R N Gunn; S R Gunn; V J Cunningham
Journal:  J Cereb Blood Flow Metab       Date:  2001-06       Impact factor: 6.200

Review 3.  Models and methods for derivation of in vivo neuroreceptor parameters with PET and SPECT reversible radiotracers.

Authors:  M Slifstein; M Laruelle
Journal:  Nucl Med Biol       Date:  2001-07       Impact factor: 2.408

4.  Estimation of kinetic parameters in graphical analysis of PET imaging data.

Authors:  R Todd Ogden
Journal:  Stat Med       Date:  2003-11-30       Impact factor: 2.373

5.  An input function estimation method for FDG-PET human brain studies.

Authors:  Hongbin Guo; Rosemary A Renaut; Kewei Chen
Journal:  Nucl Med Biol       Date:  2007-07       Impact factor: 2.408

6.  A strategy for removing the bias in the graphical analysis method.

Authors:  J Logan; J S Fowler; N D Volkow; Y S Ding; G J Wang; D L Alexoff
Journal:  J Cereb Blood Flow Metab       Date:  2001-03       Impact factor: 6.200

7.  Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects.

Authors:  J Logan; J S Fowler; N D Volkow; A P Wolf; S L Dewey; D J Schlyer; R R MacGregor; R Hitzemann; B Bendriem; S J Gatley
Journal:  J Cereb Blood Flow Metab       Date:  1990-09       Impact factor: 6.200

8.  Multicompartmental analysis of [11C]-carfentanil binding to opiate receptors in humans measured by positron emission tomography.

Authors:  J J Frost; K H Douglass; H S Mayberg; R F Dannals; J M Links; A A Wilson; H T Ravert; W C Crozier; H N Wagner
Journal:  J Cereb Blood Flow Metab       Date:  1989-06       Impact factor: 6.200

9.  Ways toward an early diagnosis in Alzheimer's disease: the Alzheimer's Disease Neuroimaging Initiative (ADNI).

Authors:  Susanne G Mueller; Michael W Weiner; Leon J Thal; Ronald C Petersen; Clifford R Jack; William Jagust; John Q Trojanowski; Arthur W Toga; Laurel Beckett
Journal:  Alzheimers Dement       Date:  2005-07       Impact factor: 21.566

10.  Synthesis and evaluation of 11C-labeled 6-substituted 2-arylbenzothiazoles as amyloid imaging agents.

Authors:  Chester A Mathis; Yanming Wang; Daniel P Holt; Guo-Feng Huang; Manik L Debnath; William E Klunk
Journal:  J Med Chem       Date:  2003-06-19       Impact factor: 7.446

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.