Literature DB >> 20490943

An electrooptical muscle contraction sensor.

Alessio Chianura, Mario E Giardini.   

Abstract

An electrooptical sensor for the detection of muscle contraction is described. Infrared light is injected into the muscle, the backscattering is observed, and the contraction is detected by measuring the change, that occurs during muscle contraction, between the light scattered in the direction parallel and perpendicular to the muscle cells. With respect to electromyography and to optical absorption-based sensors, our device has the advantage of lower invasiveness, of lower sensitivity to electromagnetic noise and to movement artifacts, and of being able to distinguish between isometric and isotonic contractions.

Mesh:

Year:  2010        PMID: 20490943     DOI: 10.1007/s11517-010-0626-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  Artefact reduction with alternative cuff configurations.

Authors:  Lotte N S Andreasen; Johannes J Struijk
Journal:  IEEE Trans Biomed Eng       Date:  2003-10       Impact factor: 4.538

Review 2.  Myoelectric signal processing for control of powered limb prostheses.

Authors:  P Parker; K Englehart; B Hudgins
Journal:  J Electromyogr Kinesiol       Date:  2006-10-11       Impact factor: 2.368

Review 3.  Prosthetic devices: challenges and implications of robotic implants and biological interfaces.

Authors:  J C K Lai; M P Schoen; A Perez Gracia; D S Naidu; S W Leung
Journal:  Proc Inst Mech Eng H       Date:  2007-02       Impact factor: 1.617

4.  Contact dermatitis to a limb prosthesis.

Authors:  Apra Sood; James S Taylor; John N Billock
Journal:  Am J Contact Dermat       Date:  2003-09

5.  Techniques of EMG signal analysis: detection, processing, classification and applications.

Authors:  M B I Raez; M S Hussain; F Mohd-Yasin
Journal:  Biol Proced Online       Date:  2006-03-23       Impact factor: 3.244

6.  Robust EMG sensing system based on data fusion for myoelectric control of a robotic arm.

Authors:  Natalia M López; Fernando di Sciascio; Carlos M Soria; Max E Valentinuzzi
Journal:  Biomed Eng Online       Date:  2009-02-25       Impact factor: 2.819

  6 in total
  2 in total

Review 1.  Non-invasive control interfaces for intention detection in active movement-assistive devices.

Authors:  Joan Lobo-Prat; Peter N Kooren; Arno H A Stienen; Just L Herder; Bart F J M Koopman; Peter H Veltink
Journal:  J Neuroeng Rehabil       Date:  2014-12-17       Impact factor: 4.262

Review 2.  The Current State of Optical Sensors in Medical Wearables.

Authors:  Erik Vavrinsky; Niloofar Ebrahimzadeh Esfahani; Michal Hausner; Anton Kuzma; Vratislav Rezo; Martin Donoval; Helena Kosnacova
Journal:  Biosensors (Basel)       Date:  2022-04-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.