Literature DB >> 14560769

Artefact reduction with alternative cuff configurations.

Lotte N S Andreasen1, Johannes J Struijk.   

Abstract

In nerve cuff electrode recordings of neural signals, the pick-up of interfering signals can be reduced by choosing appropriate cuff configurations. In the traditionally used tripolar configuration, short circuiting of the end electrodes is expected to reduce the field inside the cuff from interfering signals. A model study suggests that moving the end electrodes toward the center of the cuff reduces the pick-up of interfering signals. In this paper, these properties are studied in more detail using a rabbit model. In addition, a new cuff configuration is suggested, which has an additional set of short circuited end electrodes. The total improvement of signal-to-noise ratio in the new configuration as compared with the traditionally used tripolar configuration was 73% for muscle signals and 127% for the stimulus pulse.

Entities:  

Mesh:

Year:  2003        PMID: 14560769     DOI: 10.1109/TBME.2003.817633

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  8 in total

1.  An electrooptical muscle contraction sensor.

Authors:  Alessio Chianura; Mario E Giardini
Journal:  Med Biol Eng Comput       Date:  2010-05-21       Impact factor: 2.602

2.  Model-based evaluation of the short-circuited tripolar cuff configuration.

Authors:  Lotte N S Andreasen; Johannes J Struijk
Journal:  Med Biol Eng Comput       Date:  2006-04-26       Impact factor: 2.602

3.  Pulsed laser versus electrical energy for peripheral nerve stimulation.

Authors:  Jonathon Wells; Peter Konrad; Chris Kao; E Duco Jansen; Anita Mahadevan-Jansen
Journal:  J Neurosci Methods       Date:  2007-03-31       Impact factor: 2.390

4.  Model-based Bayesian signal extraction algorithm for peripheral nerves.

Authors:  Thomas E Eggers; Yazan M Dweiri; Grant A McCallum; Dominique M Durand
Journal:  J Neural Eng       Date:  2017-07-04       Impact factor: 5.379

Review 5.  On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion.

Authors:  Max Ortiz-Catalan; Rickard Brånemark; Bo Håkansson; Jean Delbeke
Journal:  Biomed Eng Online       Date:  2012-06-20       Impact factor: 2.819

6.  Effect on signal-to-noise ratio of splitting the continuous contacts of cuff electrodes into smaller recording areas.

Authors:  Max Ortiz-Catalan; Jorge Marin-Millan; Jean Delbeke; Bo Håkansson; Rickard Brånemark
Journal:  J Neuroeng Rehabil       Date:  2013-02-21       Impact factor: 4.262

7.  Evaluation of methods for extraction of the volitional EMG in dynamic hybrid muscle activation.

Authors:  Eran Langzam; Eli Isakov; Joseph Mizrahi
Journal:  J Neuroeng Rehabil       Date:  2006-11-23       Impact factor: 4.262

8.  Separability of neural responses to standardised mechanical stimulation of limbs.

Authors:  Emma Brunton; Christoph W Blau; Kianoush Nazarpour
Journal:  Sci Rep       Date:  2017-09-11       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.