Literature DB >> 20489678

Morphometric comparisons between the pedicle and the pedicle rib unit in the immature Chinese thoracic spine: a computed tomographic assessment.

Nai-Feng Tian1, Hua-Zi Xu, Xiang-Yang Wang, Qiao-Jie Chen, Li-Cheng Zheng.   

Abstract

STUDY
DESIGN: Morphology comparisons between the pedicle and pedicle rib unit in the immature spine were conducted through computed tomographic scans.
OBJECTIVE: To establish reference data concerning the dimensions of the pedicle rib unit for normal children. SUMMARY OF BACKGROUND DATA: Until recently, studies on extrapedicular fixation were mostly based on adults. No published study has assessed the morphology of the pedicle rib unit in the normal immature population. Establishment of the basic morphometric characteristics may be beneficial in treating immature patients with spinal disorders.
METHODS: Measurements were carried out on the chest computed tomography scans of the immature Chinese patients without any spinal disorder findings. The width, chord length, and transverse angle of the pedicle rib unit were obtained and compared with the corresponding pedicle index. Difference between sex groups was measured, and significant statistical correlations were carefully studied to determine potentially important clinical relationships.
RESULTS: The mean values and the standard deviations obtained for each thoracic segment were determined. The width, chord length, and transverse angle of the pedicle rib unit were significantly larger than corresponding pedicle measurements at all levels. Significant difference for measurements between sexes was found at some segments. Compared with the sex, age seemed to have a more significant effect on the measurements. Linear pedicle and pedicle rib unit dimensions had good correlations with age, whereas the transverse angle seemed to change little with age.
CONCLUSION: Compared with the dimensions of the immature pedicle, the significantly larger size of the corresponding pedicle rib unit provides a more ample space, which accommodates screws with larger diameters. Extrapedicular vertebral body fixation was anatomically feasible for the immature spine. The new procedure should be cautiously applied to avoid potential implant failures or a new deformity because of the growth of the immature spine.

Entities:  

Mesh:

Year:  2010        PMID: 20489678     DOI: 10.1097/BRS.0b013e3181c6d9ae

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  4 in total

Review 1.  Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies.

Authors:  Nai-Feng Tian; Qi-Shan Huang; Ping Zhou; Yang Zhou; Rui-Kai Wu; Yi Lou; Hua-Zi Xu
Journal:  Eur Spine J       Date:  2010-09-23       Impact factor: 3.134

2.  Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience.

Authors:  Ke-He Yu; Jian-Jun Hong; Xiao-Shan Guo; Dong-Sheng Zhou
Journal:  J Orthop Surg Res       Date:  2015-09-22       Impact factor: 2.359

3.  Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography.

Authors:  Jun Xuan; Jian Chen; Hui He; Hai-Ming Jin; Di Zhang; Yao-Sen Wu; Nai-Feng Tian; Xiang-Yang Wang
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.889

4.  The accuracy of a method for printing three-dimensional spinal models.

Authors:  Ai-Min Wu; Zhen-Xuan Shao; Jian-Shun Wang; Xin-Dong Yang; Wan-Qing Weng; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi; Zhong-Ke Lin
Journal:  PLoS One       Date:  2015-04-27       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.