Comparison of sequential and helical scanning for radiation dose and image quality: results of the Prospective Multicenter Study on Radiation Dose Estimates of Cardiac CT Angiography (PROTECTION) I Study.

Bernhard Bischoff1, Franziska Hein, Tanja Meyer, Markus Krebs, Martin Hadamitzky, Stefan Martinoff, Albert Schömig, Jörg Hausleiter.   

Abstract

OBJECTIVE: Concerns have been raised about the radiation exposure of coronary CT angiography (CTA). Recently, a prospective ECG-triggered sequential coronary CTA technique was developed to reduce exposure to ionizing radiation. The purpose of this analysis was to determine the impact of a sequential scanning technique on image quality and radiation dose in a prespecified subgroup analysis of the Prospective Multicenter Study on Radiation Dose Estimates of Cardiac CT Angiography I (PROTECTION I) Study when compared with a standard helical scanning technique.
MATERIALS AND METHODS: This analysis comprises 685 64-MDCT coronary angiography studies of 47 international study sites in which the image quality was assessed by an experienced coronary CTA investigator using a 4-point score (1 = nondiagnostic, 4 = excellent image quality). Image quality was analyzed in all patients studied with the sequential scanning mode (n = 99) and in randomly selected patients of the population studied with the helical acquisition mode (n = 586). Radiation dose estimates were derived from the dose-length product (DLP) and a conversion coefficient for the chest (0.014 mSv x mGy(-1) x cm(-1)).
RESULTS: Although the sequential scanning mode significantly reduced radiation dose estimates by 68% from 11.2 mSv for the helical mode to 3.6 mSv for the sequential mode (p < 0.001), the median diagnostic image quality scores were comparable in both groups. The median diagnostic score for both scanning modes was 3.5 (interquartile range: sequential vs helical mode, 3.25-3.75 vs 3.0-3.75, respectively; p = 0.62).
CONCLUSION: The results of the PROTECTION I Study suggest that the prospective ECG-triggered sequential coronary CTA technique significantly reduces radiation dose without impairing image quality when compared with the standard retrospective helical data acquisition in patients with a low and stable heart rate.

Entities:  

Mesh:

Year:  2010        PMID: 20489088     DOI: 10.2214/AJR.09.3543

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  25 in total

Review 1.  Low-dose cardiovascular computed tomography: where are the limits?

Authors:  Paul Schoenhagen; Carla M Thompson; Sandra S Halliburton
Journal:  Curr Cardiol Rep       Date:  2012-02       Impact factor: 2.931

2.  Multislice CT angiography in coronary artery disease: Technical developments, radiation dose and diagnostic value.

Authors:  Zhonghua Sun
Journal:  World J Cardiol       Date:  2010-10-26

3.  CT-angiography protocol with low dose radiation and low volume contrast medium for non-cardiac chest pain.

Authors:  Emin Cakmakci; Huseyin Ozkurt; Safiye Tokgoz; Esra Karabay; Berna Ucan; Melek Pala Akdogan; Muzaffer Basak
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 4.  Important advances in technology and unique applications to cardiovascular computed tomography.

Authors:  Kongkiat Chaikriangkrai; Su Yeon Choi; Faisal Nabi; Su Min Chang
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

Review 5.  Image quality in coronary CT angiography: challenges and technical solutions.

Authors:  Olivier Ghekiere; Rodrigo Salgado; Nico Buls; Tim Leiner; Isabelle Mancini; Piet Vanhoenacker; Paul Dendale; Alain Nchimi
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

6.  Prognostic Performance of Prospective versus Retrospective Electrocardiographic Gating in Coronary Computed Tomographic Angiography.

Authors:  Pradnya Velankar; Kongkiat Chaikriangkrai; Ninad Dewal; Sayf Khaleel Bala; Belqis Elferjani; Sama Alchalabi; Su Min Chang
Journal:  Tex Heart Inst J       Date:  2018-08-01

Review 7.  SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

Authors:  Sandra S Halliburton; Suhny Abbara; Marcus Y Chen; Ralph Gentry; Mahadevappa Mahesh; Gilbert L Raff; Leslee J Shaw; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2011 Jul-Aug

8.  Assessment of image quality and radiation dose of prospectively ECG-triggered adaptive dual-source coronary computed tomography angiography (cCTA) with arrhythmia rejection algorithm in systole versus diastole: a retrospective cohort study.

Authors:  Ashley M Lee; Jonathan Beaudoin; Leif-Christopher Engel; Manavjot S Sidhu; Suhny Abbara; Thomas J Brady; Udo Hoffmann; Brian B Ghoshhajra
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-24       Impact factor: 2.357

9.  Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch.

Authors:  Matthias S May; Paul Deak; Axel Kuettner; Michael M Lell; Wolfgang Wuest; Michael Scharf; Andrea K Keller; Lothar Häberle; Stephan Achenbach; Martin Seltmann; Michael Uder; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-10-09       Impact factor: 5.315

10.  Correlation between low tube voltage in dual source CT coronary artery imaging with image quality and radiation dose.

Authors:  Zi-Qiao Lei; Ping Han; Hai-Bo Xu; Jian-Ming Yu; Hong-Li Liu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2014-08-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.