Literature DB >> 20484215

Evaluation of microbial contamination associated with different preparation methods for neonatal intravenous fat emulsion infusion.

Catherine M Crill1, Emily B Hak, Lawrence A Robinson, Richard A Helms.   

Abstract

PURPOSE: Microbial contamination associated with different methods of neonatal intravenous fat emulsion (IVFE) preparation and delivery was evaluated.
METHODS: Sterility testing was performed on IVFE dispensed via three different methods: (1) in the original container (n = 60), (2) repackaged into a syringe (n = 90), and (3) drawdown of the original container (n = 60). At the end of each infusion (24 hours for methods 1 and 3, 12 hours for method 2), a sample of the IVFE was withdrawn from the container using a sterile syringe in an International Organization for Standardization class 5 hood and sent to the hospital microbiology laboratory, where the samples were introduced into blood culture bottles and incubated for five days. Each sample was then subcultured on a blood agar plate with olive oil and left for an additional two days in a carbon dioxide incubator to assess for Malassezia furfur.
RESULTS: None of the samples from the original containers showed bacterial or fungal growth. Three of the samples from syringes had bacterial growth (two samples contained coagulase-negative staphylococcus and one contained both Klebsiella oxytoca and Citrobacter freundii), yielding a contamination rate of 3.3%. The number of contaminated samples did not significantly differ among the three preparation methods (p = 0.13).
CONCLUSION: Repackaging IVFE into sterile syringes resulted in bacterial contamination and should be avoided in clinical practice. IVFE samples obtained using the drawdown procedure under sterile conditions for infusion over 24 hours revealed no microbial contamination.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20484215     DOI: 10.2146/ajhp090199

Source DB:  PubMed          Journal:  Am J Health Syst Pharm        ISSN: 1079-2082            Impact factor:   2.637


  8 in total

1.  Evaluating Sterility of Single Dose Vials on an Automated Compounding Device.

Authors:  Hannah M Hutchinson; Brian E Sayre; Terrence Prettyman; Erica King
Journal:  Hosp Pharm       Date:  2017-04

2.  Microbial growth in neonatal intravenous fat emulsion administered over 12 versus 24 hours.

Authors:  Bethany M Dedonato; Lisa I Bickford; Ryan J Gates
Journal:  J Pediatr Pharmacol Ther       Date:  2013-10

3.  Microbial Contamination of Neonatal Injectable Lipid Emulsions at 12 and 24 Hours' Infusion Time With Evaluation of Infection Control Measures.

Authors:  Eman A Omran; Faten F Eisa; Wafaa M K Bakr
Journal:  J Pediatr Pharmacol Ther       Date:  2020 Jan-Feb

4.  Incorrect aseptic techniques in medicine preparation and recommendations for safer practices: a systematic review.

Authors:  Eeva Suvikas-Peltonen; Suvi Hakoinen; Ercan Celikkayalar; Raisa Laaksonen; Marja Airaksinen
Journal:  Eur J Hosp Pharm       Date:  2016-10-12

Review 5.  Systematic evidence review of rates and burden of harm of intravenous admixture drug preparation errors in healthcare settings.

Authors:  Nancy Hedlund; Idal Beer; Torsten Hoppe-Tichy; Patricia Trbovich
Journal:  BMJ Open       Date:  2017-12-28       Impact factor: 2.692

Review 6.  Extemporaneous Compounding: Selective Pharmacists with Separate Skill.

Authors:  A K Mohiuddin
Journal:  Innov Pharm       Date:  2019-10-31

7.  Pharmacy compounding primer for physicians: prescriber beware.

Authors:  Sarah Sellers; Wulf H Utian
Journal:  Drugs       Date:  2012-11-12       Impact factor: 9.546

Review 8.  Risk of parenteral nutrition in neonates--an overview.

Authors:  Walter Zingg; Maren Tomaske; Maria Martin
Journal:  Nutrients       Date:  2012-10-16       Impact factor: 5.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.