Literature DB >> 20482296

Urine particle evaluation: a comparison between the UF-1000i and quantitative microscopy.

Fabio Manoni1, Agostino Tinello, Lucia Fornasiero, Paolo Hoffer, Valeria Temporin, Sara Valverde, Gianluca Gessoni.   

Abstract

BACKGROUND: The study of urine particles plays a key role in the diagnosis of kidney diseases. In this study, the authors evaluated the correlation between the UF-1000i and quantitative manual microscopy.
METHODS: A total of 214 untreated urine samples were studied using the Sysmex UF-1000i and compared with results obtained from quantitative manual microscopy using the Fuchs-Rosenthal counting chamber.
RESULTS: Using Pearson statistics, we observed satisfactory correlation between the UF-1000i and quantitative microscopy: for red blood cells (RBCs) r was 0.98, for white blood cells (WBCs) r was 1.00, for epithelial cells (EC) r was 0.96, and for casts r was 0.69. Using linear regression statistics, we also observed satisfactory correlation between the UF-1000i and quantitative microscopy: for RBCs R(2) was 0.95, for WBCs R(2) was 0.99, for EC R(2) was 0.92, and for casts R(2) was 0.48.
CONCLUSIONS: In our experience, automated urine particle analysis performed using the Sysmex UF-1000i analyzer is sufficiently precise and improves the workflow in a routine laboratory. Precision was satisfactory and concordance with the reference method is good for RBC, WBC and EC; for casts microscopic observation is required for flagged samples to discriminate hyaline from pathologic casts.

Entities:  

Mesh:

Year:  2010        PMID: 20482296     DOI: 10.1515/CCLM.2010.233

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  14 in total

1.  Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.

Authors:  Wonmok Lee; Jung-Sook Ha; Nam-Hee Ryoo
Journal:  J Clin Lab Anal       Date:  2016-02-03       Impact factor: 2.352

2.  Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.

Authors:  Maarten A C Broeren; Semiha Bahçeci; Huib L Vader; Niek L A Arents
Journal:  J Clin Microbiol       Date:  2011-01-19       Impact factor: 5.948

3.  UriSed 3 and UX-2000 automated urine sediment analyzers vs manual microscopic method: A comparative performance analysis.

Authors:  Sathima Laiwejpithaya; Preechaya Wongkrajang; Kanit Reesukumal; Chonticha Bucha; Suriya Meepanya; Chanutchaya Pattanavin; Varanya Khejonnit; Achara Chuntarut
Journal:  J Clin Lab Anal       Date:  2017-05-02       Impact factor: 2.352

4.  Automated analysis for differentiating leukocytes in body fluids using the software "biological liquid application" on ADVIA2120/2120i hematology analyzer.

Authors:  Alessandra Falda; Paolo Doretto
Journal:  J Clin Lab Anal       Date:  2018-05-25       Impact factor: 2.352

5.  Isomorphic red blood cells using automated urine flow cytometry is a reliable method in diagnosis of bladder cancer.

Authors:  Satoru Muto; Syo-Ichiro Sugiura; Akiko Nakajima; Akira Horiuchi; Masahiro Inoue; Keisuke Saito; Shuji Isotani; Raizo Yamaguchi; Hisamitsu Ide; Shigeo Horie
Journal:  Int J Clin Oncol       Date:  2013-10-09       Impact factor: 3.402

6.  Urine flow cytometry as a primary screening method to exclude urinary tract infections.

Authors:  K J M Boonen; E L Koldewijn; N L A Arents; P A M Raaymakers; V Scharnhorst
Journal:  World J Urol       Date:  2012-05-16       Impact factor: 4.226

7.  Rapid discrimination of Gram-positive and Gram-negative bacteria in liquid samples by using NaOH-sodium dodecyl sulfate solution and flow cytometry.

Authors:  Atsushi Wada; Mari Kono; Sawako Kawauchi; Yuri Takagi; Takashi Morikawa; Kunihiro Funakoshi
Journal:  PLoS One       Date:  2012-10-15       Impact factor: 3.240

8.  Levels of albuminuria and risk of developing macroalbuminuria in type 2 diabetes: historical cohort study.

Authors:  Shoma Chida; Yoshikuni Fujita; Akifumi Ogawa; Akinori Hayashi; Raishi Ichikawa; Yuji Kamata; Akihiro Takeuchi; Koji Takano; Masayoshi Shichiri
Journal:  Sci Rep       Date:  2016-05-23       Impact factor: 4.379

9.  Diagnostic accuracy of urinary prostate protein glycosylation profiling in prostatitis diagnosis.

Authors:  Tijl Vermassen; Charles Van Praet; Filip Poelaert; Nicolaas Lumen; Karel Decaestecker; Piet Hoebeke; Simon Van Belle; Sylvie Rottey; Joris Delanghe
Journal:  Biochem Med (Zagreb)       Date:  2015-10-15       Impact factor: 2.313

10.  [URISCAM project: Multicenter evaluation of the UF-Series cytometer in the urinary tract infections screening].

Authors:  M M Jarabo; M A Asencio; R Carranza; O Herráez; M Huertas; A Arias-Arias; O Redondo; M A Galán; M S Illescas; P Zamarrón; S Solís; S Jiménez-Alvarez
Journal:  Rev Esp Quimioter       Date:  2018-01-29       Impact factor: 1.553

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.