INTRODUCTION: The aim of this part of an ongoing study was to describe the dentin removal ability of a novel nickel-titanium instrument, the self-adjusting file (SAF), by using micro-computed tomography.
METHODS: Twenty maxillary incisors were scanned preoperatively at 20-microm resolution and postoperatively after up to 6 minutes of preparation with an SAF with 1.5-mm or 2-mm diameter. SAFs were operated with continuous irrigation in a handpiece that provided an oscillating, in-and-out movement. Changes in canal volume compared with preoperative values as well as unprepared canal surface area were determined. Data were normally distributed and compared by analysis of variance and regression analyses.
RESULTS: Preoperatively canal volumes were statistically similar in both groups (9.86 +/- 3.97 mm3 and 9.80 +/- 2.67 mm3). Volumes increased during preparation to 13.58 +/- 3.85 mm3 (after 6 minutes with SAF 1.5 mm) and 16.43 +/- 3.64 mm3 (after 5 minutes with SAF 2.0 mm), and overall canal shapes were adequate. Unprepared canal surface area decreased from 63.0% +/- 15.1% (2 minutes with SAF 1.5 mm) to 8.6% +/- 4.1% (5 minutes with SAF 2.0 mm).
CONCLUSIONS: Preparation of straight root canals in maxillary anterior teeth left little canal surface uninstrumented after shaping with the SAF. The timeframe of clinical application will depend on the amount of desired dentin removal and done with an SAF selected on the basis of apical gauging. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20478468     DOI: 10.1016/j.joen.2010.02.023

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  20 in total

1.  Modifications in Canal Anatomy of Curved Canals of Mandibular First Molars by two Glide Path Instruments using CBCT.

Authors:  Anil Dhingra; Nayasha Manchanda
Journal:  J Clin Diagn Res       Date:  2014-11-20

2.  Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT: author response.

Authors:  O Peters; D Maret
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

3.  Root and Root Canal Configuration Characterization Using Microcomputed Tomography: A Systematic Review.

Authors:  Mohmed Isaqali Karobari; Sohaib Arshad; Tahir Yusuf Noorani; Naveed Ahmed; Syed Nahid Basheer; Syed Wali Peeran; Anand Marya; Charu Mohan Marya; Pietro Messina; Giuseppe Alessandro Scardina
Journal:  J Clin Med       Date:  2022-04-20       Impact factor: 4.964

4.  Smear layer removal in canals shaped with reciprocating rotary systems.

Authors:  Paula Amaral; Leopoldo Forner; Carmen Llena
Journal:  J Clin Exp Dent       Date:  2013-12-01

Review 5.  The self-adjusting file (SAF) system: An evidence-based update.

Authors:  Zvi Metzger
Journal:  J Conserv Dent       Date:  2014-09

6.  Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study.

Authors:  Emmanuel João Nogueira Leal da Silva; Sara Gomes de Moura; Carolina Oliveira de Lima; Ana Flávia Almeida Barbosa; Waleska Florentino Misael; Mariane Floriano Lopes Santos Lacerda; Luciana Moura Sassone
Journal:  Restor Dent Endod       Date:  2021-02-25

7.  Irrigation of human prepared root canal--ex vivo based computational fluid dynamics analysis.

Authors:  Damir Snjaric; Zoran Carija; Alen Braut; Adelaida Halaji; Maja Kovacevic; Davor Kuis
Journal:  Croat Med J       Date:  2012-10       Impact factor: 1.351

8.  The efficacy of the self-adjusting file and ProTaper for removal of calcium hydroxide from root canals.

Authors:  Gisele Faria; Milton Carlos Kuga; Alessandra Camila Ruy; Arturo Javier Aranda-Garcia; Idomeo Bonetti-Filho; Juliane Maria Guerreiro-Tanomaru; Renato Toledo Leonardo
Journal:  J Appl Oral Sci       Date:  2013 Jul-Aug       Impact factor: 2.698

9.  Efficiency of the Self Adjusting File, WaveOne, Reciproc, ProTaper and hand files in root canal debridement.

Authors:  K Meltem Topcu; Ertugrul Karatas; Damla Ozsu; Ibrahim Ersoy
Journal:  Eur J Dent       Date:  2014-07

10.  In vitro investigation of the cleaning efficacy, shaping ability, preparation time and file deformation of continuous rotary, reciprocating rotary and manual instrumentations in primary molars.

Authors:  Nahid Ramazani; Abbas Mohammadi; Foroogh Amirabadi; Mohsen Ramazani; Farzane Ehsani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-03-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.