Literature DB >> 20473627

Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope.

Tomonori Oie1, Hisato Suzuki, Yoshinobu Murayama, Toru Fukuda, Sadao Omata, Keiichi Kanda, Keiichi Takamizawa, Yasuhide Nakayama.   

Abstract

The objective of this study was to make an elasticity distribution image of natural arteries in a liquid environment at high resolution at the micrometer level and at a wide area at the sub-square millimeter level by improving the scanning haptic microscope (SHM), developed previously for characterization of the stiffness of natural tissues. The circumferential sections (thickness, 1.0 mm) of small-caliber porcine arteries (approximately 3-mm diameter) were used as a sample. Measurement was performed by soaking a probe (diameter, 5 microm; spatial resolution, less than 2 microm) in saline solution at an appropriate depth. The vascular tissues were segregated by multi-layering a high elasticity region with mainly elastin (50.8 +/- 13.8 kPa) and a low one with mainly collagen and smooth muscle cells (17.0 +/- 9.0 kPa), as observed previously in high humidity conditions. The elasticity was measured repeatedly with little change for over 4 h in a liquid environment, which enabled observation with maintenance of high precision of a large area of at least 1,200 x 100 microm, whereas the elasticity was increased with time by the dehydration of samples with shrinkage in the air, in which an averaged elasticity in the overall area was approximately doubled within 2 h. This simple, inexpensive system allows observation of the distribution of the surface elasticity at the extracellular matrix level of vascular tissues in a liquid environment close to the natural one.

Entities:  

Mesh:

Year:  2010        PMID: 20473627     DOI: 10.1007/s10047-010-0503-2

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  16 in total

1.  Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement.

Authors:  Yoshinobu Murayama; Christos E Constantinou; Sadao Omata
Journal:  J Biomech       Date:  2004-01       Impact factor: 2.712

2.  Tactile mapping system: a novel imaging technology for surface topography and elasticity of tissues or organs.

Authors:  Tomonori Oie; Hisato Suzuki; Toru Fukuda; Yoshinobu Murayama; Sadao Omata; Keiichi Kanda; Yasuhide Nakayama
Journal:  Innovations (Phila)       Date:  2009-11

3.  Atomic force microscope.

Authors: 
Journal:  Phys Rev Lett       Date:  1986-03-03       Impact factor: 9.161

4.  Development of a completely autologous valved conduit with the sinus of Valsalva using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model.

Authors:  Masashi Yamanami; Yuki Yahata; Masami Uechi; Megumi Fujiwara; Hatsue Ishibashi-Ueda; Keiichi Kanda; Taiji Watanabe; Tsutomu Tajikawa; Kenkichi Ohba; Hitoshi Yaku; Yasuhide Nakayama
Journal:  Circulation       Date:  2010-09-14       Impact factor: 29.690

5.  Assessment of elasticity and topography of Aspergillus nidulans spores via atomic force microscopy.

Authors:  Liming Zhao; David Schaefer; Mark R Marten
Journal:  Appl Environ Microbiol       Date:  2005-02       Impact factor: 4.792

6.  A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues.

Authors:  Jeffrey G Jacot; Scott Dianis; Joshua Schnall; Joyce Y Wong
Journal:  J Biomed Mater Res A       Date:  2006-12-01       Impact factor: 4.396

7.  A pinch elastometer for soft tissue.

Authors:  S M Harrison; M B Bush; P E Petros
Journal:  Med Eng Phys       Date:  2006-06-05       Impact factor: 2.242

8.  Development of biotube vascular grafts incorporating cuffs for easy implantation.

Authors:  Taiji Watanabe; Keiichi Kanda; Hatsue Ishibashi-Ueda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2007-03-23       Impact factor: 1.731

9.  Autologous small-caliber "biotube" vascular grafts with argatroban loading: a histomorphological examination after implantation to rabbits.

Authors:  Taiji Watanabe; Keiichi Kanda; Hatsue Ishibashi-Ueda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-01       Impact factor: 3.368

10.  Mechanical imaging of the breast.

Authors:  Vladimir Egorov; Armen P Sarvazyan
Journal:  IEEE Trans Med Imaging       Date:  2008-09       Impact factor: 10.048

View more
  5 in total

Review 1.  Journal of Artificial Organs 2010: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2011-03-16       Impact factor: 1.731

2.  Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM).

Authors:  Takeshi Moriwaki; Tomonori Oie; Keiichi Takamizawa; Yoshinobu Murayama; Toru Fukuda; Sadao Omata; Keiichi Kanda; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2011-08-20       Impact factor: 1.731

3.  Observation of local elastic distribution in aortic tissues under static strain condition by use of a scanning haptic microscope.

Authors:  Takeshi Moriwaki; Tomonori Oie; Keiichi Takamizawa; Yoshinobu Murayama; Toru Fukuda; Sadao Omata; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2012-11-23       Impact factor: 1.731

4.  Pyrrole-imidazole polyamide targeting transforming growth factor β1 ameliorates encapsulating peritoneal sclerosis.

Authors:  Kazuo Serie; Noboru Fukuda; Shigeki Nakai; Hiroyuki Matsuda; Takashi Maruyama; Yoshinobu Murayama; Sadao Omata
Journal:  Perit Dial Int       Date:  2012-01-03       Impact factor: 1.756

5.  Advantages and Challenges of Relaxor-PbTiO3 Ferroelectric Crystals for Electroacoustic Transducers- A Review.

Authors:  Shujun Zhang; Fei Li; Xiaoning Jiang; Jinwook Kim; Jun Luo; Xuecang Geng
Journal:  Prog Mater Sci       Date:  2015-03-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.