Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM).

Takeshi Moriwaki1, Tomonori Oie, Keiichi Takamizawa, Yoshinobu Murayama, Toru Fukuda, Sadao Omata, Keiichi Kanda, Yasuhide Nakayama.   

Abstract

Variations in microscopic elastic structures along the entire length of canine aorta were evaluated by use of a scanning haptic microscope (SHM). The total aorta from the aortic arch to the abdominal aorta was divided into 6 approximately equal segments. After embedding the aorta in agar, it was cut into horizontal circumferential segments to obtain disk-like agar portions containing ring-like samples of aorta with flat surfaces (thickness, approximately 1 mm). The elastic modulus and topography of the samples under no-load conditions were simultaneously measured along the entire thickness of the wall by SHM by using a probe with a diameter of 5 μm and a spatial resolution of 2 μm at a rate of 0.3 s/point. The elastic modulus of the wall was the highest on the side of the luminal surface and decreased gradually toward the adventitial side. This tendency was similar to that of the change in the elastin fiber content. During the evaluation of the mid-portion of each tunica media segment, the highest elastic modulus (40.8 ± 3.5 kPa) was identified at the thoracic section of the aorta that had the highest density of elastic fibers. Under no-load conditions, portions of the aorta with high elastin density have a high elastic modulus.

Entities:  

Mesh:

Year:  2011        PMID: 21858475     DOI: 10.1007/s10047-011-0596-2

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  20 in total

Review 1.  Elastic proteins: biological roles and mechanical properties.

Authors:  John Gosline; Margo Lillie; Emily Carrington; Paul Guerette; Christine Ortlepp; Ken Savage
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2002-02-28       Impact factor: 6.237

2.  Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement.

Authors:  Yoshinobu Murayama; Christos E Constantinou; Sadao Omata
Journal:  J Biomech       Date:  2004-01       Impact factor: 2.712

3.  Atomic force microscope.

Authors: 
Journal:  Phys Rev Lett       Date:  1986-03-03       Impact factor: 9.161

4.  Development of a completely autologous valved conduit with the sinus of Valsalva using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model.

Authors:  Masashi Yamanami; Yuki Yahata; Masami Uechi; Megumi Fujiwara; Hatsue Ishibashi-Ueda; Keiichi Kanda; Taiji Watanabe; Tsutomu Tajikawa; Kenkichi Ohba; Hitoshi Yaku; Yasuhide Nakayama
Journal:  Circulation       Date:  2010-09-14       Impact factor: 29.690

5.  Surgical thoracic sympathectomy induces structural and biomechanical remodeling of the thoracic aorta in a porcine model.

Authors:  Dimitrios C Angouras; Theodosios J Dosios; Constantinos A Dimitriou; Themistocles P Chamogeorgakis; Chris K Rokkas; Themistoklis A Manos; Dimitrios P Sokolis
Journal:  J Surg Res       Date:  2010-09-17       Impact factor: 2.192

6.  A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues.

Authors:  Jeffrey G Jacot; Scott Dianis; Joshua Schnall; Joyce Y Wong
Journal:  J Biomed Mater Res A       Date:  2006-12-01       Impact factor: 4.396

7.  Segmental differences of aortic function and composition: clinical implications.

Authors:  Dimitrios P Sokolis; Harisios Boudoulas; Panayotis E Karayannacos
Journal:  Hellenic J Cardiol       Date:  2008 May-Jun

8.  Autologous small-caliber "biotube" vascular grafts with argatroban loading: a histomorphological examination after implantation to rabbits.

Authors:  Taiji Watanabe; Keiichi Kanda; Hatsue Ishibashi-Ueda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-01       Impact factor: 3.368

9.  Collagen and elastin content in canine arteries selected from functionally different vascular beds.

Authors:  G M Fischer; J G Llaurado
Journal:  Circ Res       Date:  1966-08       Impact factor: 17.367

10.  Local mechanical and structural properties of healthy and diseased human ascending aorta tissue.

Authors:  Nusrat Choudhury; Olivier Bouchot; Leonie Rouleau; Dominique Tremblay; Raymond Cartier; Jagdish Butany; Rosaire Mongrain; Richard L Leask
Journal:  Cardiovasc Pathol       Date:  2008-03-05       Impact factor: 2.185

View more
  7 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

2.  Observation of local elastic distribution in aortic tissues under static strain condition by use of a scanning haptic microscope.

Authors:  Takeshi Moriwaki; Tomonori Oie; Keiichi Takamizawa; Yoshinobu Murayama; Toru Fukuda; Sadao Omata; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2012-11-23       Impact factor: 1.731

3.  An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

Authors:  Mark A Wierzbicki; Sarah B Raines; Sonya G Gordon; John C Criscione; Ashley B Saunders; Scott Birch; Bradley Due; Brandis Keller; Landon D Nash; Matthew W Miller; Duncan J Maitland
Journal:  J Mech Behav Biomed Mater       Date:  2017-07-25

4.  Mechanical and in vitro evaluation of an experimental canine patent ductus arteriosus occlusion device.

Authors:  Mark A Wierzbicki; Jesse Bryant; Matthew W Miller; Brandis Keller; Duncan J Maitland
Journal:  J Mech Behav Biomed Mater       Date:  2015-12-21

5.  Quantification of the regional bioarchitecture in the human aorta.

Authors:  J Concannon; P Dockery; A Black; S Sultan; N Hynes; P E McHugh; K M Moerman; J P McGarry
Journal:  J Anat       Date:  2019-09-11       Impact factor: 2.610

6.  Height and Mortality from Aortic Aneurysm and Dissection.

Authors:  Midori Takada; Kazumasa Yamagishi; Akiko Tamakoshi; Hiroyasu Iso
Journal:  J Atheroscler Thromb       Date:  2021-09-02       Impact factor: 4.394

7.  Rapid evaporative ionization mass spectrometry (intelligent knife) for point-of-care testing in acute aortic dissection surgery.

Authors:  Hannah A Davies; Eva Caamano-Gutierrez; Joscelyn Sarsby; Ya Hua Chim; Steve Barrett; Omar Nawaytou; Amer Harky; Mark Field; Riaz Akhtar; Jillian Madine
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-05-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.