Literature DB >> 20472369

In vivo proton beam range verification using spine MRI changes.

Michael F Gensheimer1, Torunn I Yock, Norbert J Liebsch, Gregory C Sharp, Harald Paganetti, Neel Madan, P Ellen Grant, Thomas Bortfeld.   

Abstract

PURPOSE: In proton therapy, uncertainty in the location of the distal dose edge can lead to cautious treatment plans that reduce the dosimetric advantage of protons. After radiation exposure, vertebral bone marrow undergoes fatty replacement that is visible on magnetic resonance imaging (MRI). This presents an exciting opportunity to observe radiation dose distribution in vivo. We used quantitative spine MRI changes to precisely detect the distal dose edge in proton radiation patients. METHODS AND MATERIALS: We registered follow-up T1-weighted MRI images to planning computed tomography scans from 10 patients who received proton spine irradiation. A radiation dose-MRI signal intensity curve was created using the lateral beam penumbra in the sacrum. This curve was then used to measure range errors in the lumbar spine.
RESULTS: In the lateral penumbra, there was an increase in signal intensity with higher dose throughout the full range of 0-37.5 Gy (RBE). In the distal fall-off region, the beam sometimes appeared to penetrate farther than planned. The mean overshoot in 10 patients was 1.9 mm (95% confidence interval, 0.8-3.1 mm), on the order of the uncertainties inherent to our range verification method.
CONCLUSIONS: We have demonstrated in vivo proton range verification using posttreatment spine MRI changes. Our analysis suggests the presence of a systematic overshoot of a few millimeters in some proton spine treatments, but the range error does not exceed the uncertainty incorporated into the treatment planning margin. It may be possible to extend our technique to MRI sequences that show early bone marrow changes, enabling adaptive treatment modification. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20472369     DOI: 10.1016/j.ijrobp.2009.11.060

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  20 in total

1.  Monitoring proton therapy with PET.

Authors:  H Paganetti; G El Fakhri
Journal:  Br J Radiol       Date:  2015-05-20       Impact factor: 3.039

2.  Intensity modulated proton therapy.

Authors:  H M Kooy; C Grassberger
Journal:  Br J Radiol       Date:  2015-05-27       Impact factor: 3.039

Review 3.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 4.  The physical basis and future of radiation therapy.

Authors:  T Bortfeld; R Jeraj
Journal:  Br J Radiol       Date:  2011-06       Impact factor: 3.039

5.  New developments in treatment planning and verification of particle beam therapy.

Authors:  Reinhard W Schulte; Andrew J Wroe
Journal:  Transl Cancer Res       Date:  2012-10-01       Impact factor: 1.241

Review 6.  The physics of proton therapy.

Authors:  Wayne D Newhauser; Rui Zhang
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

7.  The effects of Compton camera data acquisition and readout timing on PG imaging for proton range verification.

Authors:  Jerimy C Polf; Paul Maggi; Rajesh Panthi; Stephen Peterson; Dennis Mackin; Sam Beddar
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-02-05

Review 8.  Clinical controversies: proton therapy for pediatric tumors.

Authors:  Thomas E Merchant
Journal:  Semin Radiat Oncol       Date:  2013-04       Impact factor: 5.934

Review 9.  Range uncertainties in proton therapy and the role of Monte Carlo simulations.

Authors:  Harald Paganetti
Journal:  Phys Med Biol       Date:  2012-05-09       Impact factor: 3.609

10.  Secondary Particle Interactions in a Compton Camera Designed for in vivo Range Verification of Proton Therapy.

Authors:  Rajesh Panthi; Paul Maggi; Stephen Peterson; Dennis Mackin; Jerimy Polf; Sam Beddar
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-10-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.