Literature DB >> 20471216

Bedside placement of an aortic occlusion balloon to control a ruptured aorto-esophageal fistula in a small child.

Sarah J Hill1, Abdalla E Zarroug, Richard R Ricketts, Ravi Veeraswamy.   

Abstract

A child had a percutaneous endoscopic gastrostomy tube removed by transecting it at skin level. The internal portion ("the bolster") was allowed to pass in the GI tract. She subsequently had odynophagia. Magnetic resonance imaging identified a foreign body within the lower thoracic esophagus. During esophagoscopy, the bolster was removed. The following morning, she had massive hematemesis with cardiovascular collapse. As an emergent maneuver, an intra-aortic balloon was percutaneously deployed at the bedside without fluoroscopic guidance. This temporized the exsanguination. Subsequent intraoperative aortography confirmed an aortoesophageal fistula. A stent-graft was deployed with immediate hemodynamic stabilization. She later underwent esophageal resection and recovered well. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20471216     DOI: 10.1016/j.avsg.2009.12.016

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  8 in total

Review 1.  [Resuscitative endovascular balloon occlusion of the aorta : Option for incompressible trunk bleeding?]

Authors:  J Knapp; M Bernhard; T Haltmeier; D Bieler; B Hossfeld; M Kulla
Journal:  Anaesthesist       Date:  2018-04       Impact factor: 1.041

2.  A 2-Year-Old Boy Who Developed an Aortoesophageal Fistula After Swallowing a Button Battery, Managed Using a Novel Procedure with Vascular Plug Device as a Bridge to Definitive Surgical Repair.

Authors:  Khalid M Alreheili; Mansour Almutairi; Ali Alsaadi; Ghousia Ahmed; Abdulrahman Alhejili; Taha AlKhatrawi
Journal:  Am J Case Rep       Date:  2021-08-18

Review 3.  Button Battery Ingestion in Children: A Paradigm for Management of Severe Pediatric Foreign Body Ingestions.

Authors:  Kristina Leinwand; David E Brumbaugh; Robert E Kramer
Journal:  Gastrointest Endosc Clin N Am       Date:  2016-01

4.  Morphometric and Physiologic Modeling Study for Endovascular Occlusion in Pediatric Trauma Patients.

Authors:  Louis Carrillo; Max Skibber; Akshita Kumar; Mitchell George; Shahroz Aziz; Matthew T Harting; Laura J Moore; Charles S Cox
Journal:  ASAIO J       Date:  2020-01       Impact factor: 3.826

5.  Quantifying the need for pediatric REBOA: A gap analysis.

Authors:  Christina M Theodorou; A Francois Trappey; Carl A Beyer; Kaeli J Yamashiro; Shinjiro Hirose; Joseph M Galante; Alana L Beres; Jacob T Stephenson
Journal:  J Pediatr Surg       Date:  2020-09-22       Impact factor: 2.549

6.  Resuscitative endovascular balloon occlusion of the aorta for uncontrollable nonvariceal upper gastrointestinal bleeding.

Authors:  Hidefumi Sano; Junya Tsurukiri; Akira Hoshiai; Taishi Oomura; Yosuke Tanaka; Shoichi Ohta
Journal:  World J Emerg Surg       Date:  2016-05-20       Impact factor: 5.469

Review 7.  A systematic review and meta-analysis of the use of resuscitative endovascular balloon occlusion of the aorta in the management of major exsanguination.

Authors:  B L S Borger van der Burg; Thijs T C F van Dongen; J J Morrison; P P A Hedeman Joosten; J J DuBose; T M Hörer; R Hoencamp
Journal:  Eur J Trauma Emerg Surg       Date:  2018-05-21       Impact factor: 3.693

8.  Lethal Bleeding from a Duodenal Cancerous Ulcer Communicating with the Superior Mesenteric Artery in a Patient with Pancreatic Head Cancer.

Authors:  Yoshifumi Morita; Takanori Sakaguchi; Ryo Kitajima; Satoru Furuhashi; Ryota Kiuchi; Makoto Takeda; Takanori Hiraide; Yasushi Shibasaki; Hirotoshi Kikuchi; Yuji Suzuki; Kei Tsukamoto; Tomoharu Matsuura; Hiroya Takeuchi
Journal:  Case Rep Gastroenterol       Date:  2018-08-23
  8 in total