Literature DB >> 30913102

Morphometric and Physiologic Modeling Study for Endovascular Occlusion in Pediatric Trauma Patients.

Louis Carrillo1, Max Skibber1, Akshita Kumar1, Mitchell George1, Shahroz Aziz2, Matthew T Harting1, Laura J Moore3, Charles S Cox1.   

Abstract

The use of the resuscitative endovascular balloon occlusion of the aorta (REBOA) device is expanding in adult trauma. Reports of its use in pediatric patients have been published, but no guidelines currently exist nor has it been Food and Drug Administration approved in pediatrics. This project develops a model to determine appropriate balloon inflation volumes in pediatric patients to guide potential use. Artificial aortas were three-dimensional (3D) printed using synthetic polymers. Segments were created based on aortic diameters from 289 pediatric trauma patients' computer tomography (CT) scans. These aortic segments were inserted into a circulatory system model featuring two branches to simulate abdominal and upper body perfusion (cerebral, cardiac, and upper extremities). Sonographic flow meters and pressure transducers were placed along the circuit, and measurements were recorded as a REBOA device was inflated in the aortic segment. A negative sigmoidal relationship was observed between device inflation and aortic flow occlusion, with the initial 50% of inflation causing a 10% reduction in flow, followed by a steep decline. With increasing inflation, distal aortic flow and pressure were found to have an inverse relationship with the upper body branch metrics. In conclusion, pediatric patients present with a range of vessel diameters that occlude at various REBOA balloon inflation volumes. This study provides a basis to establish initial inflation volumes for safe REBOA deployment in appropriate pediatric trauma patients.

Entities:  

Mesh:

Year:  2020        PMID: 30913102      PMCID: PMC6856426          DOI: 10.1097/MAT.0000000000000961

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   3.826


  11 in total

Review 1.  Resuscitative endovascular balloon occlusion of the aorta (REBOA) as an adjunct for hemorrhagic shock.

Authors:  Adam Stannard; Jonathan L Eliason; Todd E Rasmussen
Journal:  J Trauma       Date:  2011-12

2.  The impact of hypovolaemic shock on the aortic diameter in a porcine model.

Authors:  F H W Jonker; H Mojibian; F J V Schlösser; D M Botta; J E Indes; F L Moll; B E Muhs
Journal:  Eur J Vasc Endovasc Surg       Date:  2010-08-19       Impact factor: 7.069

3.  Aortic endograft sizing in trauma patients with hemodynamic instability.

Authors:  Frederik H W Jonker; Hence J M Verhagen; Hamid Mojibian; Kimberly A Davis; Frans L Moll; Bart E Muhs
Journal:  J Vasc Surg       Date:  2010-05-23       Impact factor: 4.268

4.  Aortic dimensions and the risk of dissection.

Authors:  Raimund Erbel; Holger Eggebrecht
Journal:  Heart       Date:  2006-01       Impact factor: 5.994

5.  Resuscitative endovascular balloon occlusion of the aorta in trauma patients in youth.

Authors:  Tatsuya Norii; Shin Miyata; Yusuke Terasaka; Sundeep Guliani; Stephen W Lu; Cameron Crandall
Journal:  J Trauma Acute Care Surg       Date:  2017-05       Impact factor: 3.313

6.  Determining the normal aorta size in children.

Authors:  Shilpa V Hegde; Shelly Y Lensing; S Bruce Greenberg
Journal:  Radiology       Date:  2014-11-26       Impact factor: 11.105

7.  The average body surface area of adult cancer patients in the UK: a multicentre retrospective study.

Authors:  Joseph J Sacco; Joanne Botten; Fergus Macbeth; Adrian Bagust; Peter Clark
Journal:  PLoS One       Date:  2010-01-28       Impact factor: 3.240

8.  Pediatric thoracic aorta: normal measurements determined with CT.

Authors:  S W Fitzgerald; J S Donaldson; A K Poznanski
Journal:  Radiology       Date:  1987-12       Impact factor: 11.105

9.  Normal values for aortic diameters in children and adolescents--assessment in vivo by contrast-enhanced CMR-angiography.

Authors:  Thomas Kaiser; Christian J Kellenberger; Manuela Albisetti; Eva Bergsträsser; Emanuela R Valsangiacomo Buechel
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-05       Impact factor: 5.364

10.  Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing.

Authors:  Giovanni Biglino; Peter Verschueren; Raf Zegels; Andrew M Taylor; Silvia Schievano
Journal:  J Cardiovasc Magn Reson       Date:  2013-01-16       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.