Literature DB >> 20467608

One-stage versus two-stage implant placement. A Cochrane systematic review of randomised controlled clinical trials.

Marco Esposito1, Maria Gabriella Grusovin, Yun Shane Chew, Paul Coulthard, Helen V Worthington.   

Abstract

OBJECTIVES: To evaluate if a one-stage implant placement procedure is as effective as a two-stage procedure. DATA SOURCES: The Cochrane Oral Health Group's Trials Register, CENTRAL, MEDLINE and EMBASE, were searched and several journals were hand-searched with no language restriction up to January 2009. REVIEW
METHODS: All randomised controlled trials (RCTs) of osseointegrated dental implants comparing the same dental implants placed according to one- versus two-stage procedures with a minimum follow up of 6 months after loading were eligible. Screening of studies, quality assessment and data extraction were conducted in duplicate. Outcome measures were: prosthesis failure, implant failures, radiographic marginal bone level changes, patient preference including aesthetics, aesthetics evaluated by clinicians and complications.
RESULTS: Five RCTs were identified and included reporting data on 239 patients in total. On a patient basis, rather than a per implant basis, the meta-analyses showed no statistically significant differences for prosthesis and implant failures, though trends, especially in fully edentulous patients, favoured two-stage (submerged) implants.
CONCLUSIONS: The number of patients included in the trials was too small to draw definitive conclusions. The one-stage approach might be preferable in partially edentulous patients since it avoids one surgical intervention and shortens treatment times, while a two-stage submerged approach could be indicated when an implant has not obtained an optimal primary stability, when barriers are used for guided tissue regeneration or when it is expected that removable temporary prostheses could transmit excessive forces on the penetrating abutments, especially in fully edentulous patients.

Entities:  

Mesh:

Year:  2009        PMID: 20467608

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  7 in total

Review 1.  The management of severe hypodontia. Part 2: bone augmentation and the provision of implant supported prostheses.

Authors:  K Durey; L Carter; M Chan
Journal:  Br Dent J       Date:  2014-01       Impact factor: 1.626

2.  A Comparative Study of Clinical Parameters in Submerged and Non submerged Implants.

Authors:  Parviz Torkzaban; Seyed Reza Arabi; Ghodratollah Roshanaei; Mohsen Rostami; Sara Soheilifar
Journal:  J Clin Diagn Res       Date:  2015-03-01

3.  A non-interventional multicenter study to document the implants success and survival rates in daily dental practices of the CONELOG screw-line implant.

Authors:  Claudio Cacaci; Karl-Ludwig Ackermann; Thomas Barth; Steffen Kistler; Michael Stiller; Markus Schlee
Journal:  Clin Oral Investig       Date:  2018-10-15       Impact factor: 3.573

4.  Short implants: A systematic review.

Authors:  I Karthikeyan; Shrikar R Desai; Rika Singh
Journal:  J Indian Soc Periodontol       Date:  2012-07

5.  Clinical and radiographics results at 3 years of RCT with split-mouth design of submerged vs. nonsubmerged single laser-microgrooved implants in posterior areas.

Authors:  Renzo Guarnieri; Dario Di Nardo; Gianni Di Giorgio; Gabriele Miccoli; Luca Testarelli
Journal:  Int J Implant Dent       Date:  2019-12-18

6.  Long-term results of immediate implantation in the maxillary molar area with simultaneous sinus floor elevation by the crestal approach and early loading protocol: A retrospective case series follow-up study.

Authors:  Nader Ayubian Markazi; Nasrin Akhondi; Mostafa Montazeri
Journal:  J Adv Periodontol Implant Dent       Date:  2018-12-25

7.  Under-Drilling versus Hybrid Osseodensification Technique: Differences in Implant Primary Stability and Bone Density of the Implant Bed Walls.

Authors:  Rafael Delgado-Ruiz; Joshua Gold; Tanya Somohano Marquez; Georgios Romanos
Journal:  Materials (Basel)       Date:  2020-01-15       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.