Literature DB >> 20466351

Cardiovascular imaging with computed tomography: responsible steps to balancing diagnostic yield and radiation exposure.

Sandra S Halliburton1, Paul Schoenhagen.   

Abstract

Cardiovascular computed tomography (CT) is at the center of the risk-benefit debate about ionizing radiation exposure to the public from medical procedures. Although the risk has been sensationalized, the cardiovascular CT community has responded to the scrutiny by increasing efforts to ensure the responsible use of this young technology. Efforts to date have primarily included the development of appropriateness criteria and the implementation of dose-lowering techniques. Still needed is the development of standards that incorporate radiation exposure optimization into scan protocol selection. Such standards must consider applied radiation in the context of the clinical indication as well as the characteristics of the patient and provide guidance with regard to specific parameter settings. This editorial viewpoint demonstrates the need for comprehensive, individualized review of the clinical scenario before performing a cardiovascular CT, as well as the need for standards. If cardiovascular CT is the appropriate test and scan parameters are optimized with respect to radiation exposure, benefit should necessarily outweigh potential risk. However, efforts to promote responsible cardiovascular CT imaging must continue to ensure this is true for every patient. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20466351     DOI: 10.1016/j.jcmg.2010.03.004

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  8 in total

1.  Chest radiography is a poor predictor of left ventricular lead position in patients undergoing cardiac resynchronization therapy: comparison with multidetector computed tomography.

Authors:  John Rickard; Christopher Ingelmo; Dan Sraow; Bruce L Wilkoff; Richard A Grimm; Paul Schoenhagen; Patrick J Tchou; Milind Y Desai
Journal:  J Interv Card Electrophysiol       Date:  2011-05-17       Impact factor: 1.900

Review 2.  Advanced 3-D analysis, client-server systems, and cloud computing-Integration of cardiovascular imaging data into clinical workflows of transcatheter aortic valve replacement.

Authors:  Paul Schoenhagen; Mathis Zimmermann; Juergen Falkner
Journal:  Cardiovasc Diagn Ther       Date:  2013-06

Review 3.  Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

Authors:  Paul Schoenhagen; Jörg Hausleiter; Stephan Achenbach; Milind Y Desai; E Murat Tuzcu
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

Review 4.  Transcatheter aortic valve repair, imaging, and electronic imaging health record.

Authors:  Paul Schoenhagen; Juergen Falkner; David Piraino
Journal:  Curr Cardiol Rep       Date:  2013-01       Impact factor: 2.931

5.  Diagnostic yield of delayed phase imaging in CT angiography of the head and neck: a retrospective study.

Authors:  Debbie L Bennett; Leena M Hamberg; Bing Wang; Joshua A Hirsch; R Gilberto González; George J Hunter
Journal:  PLoS One       Date:  2014-06-06       Impact factor: 3.240

Review 6.  Cardiovascular diseases related to ionizing radiation: The risk of low-dose exposure (Review).

Authors:  Bjorn Baselet; Charlotte Rombouts; Abderrafi Mohammed Benotmane; Sarah Baatout; An Aerts
Journal:  Int J Mol Med       Date:  2016-10-17       Impact factor: 4.101

Review 7.  Radiation-Induced Heart Diseases: Protective Effects of Natural Products.

Authors:  Ahmed Eleojo Musa; Dheyauldeen Shabeeb
Journal:  Medicina (Kaunas)       Date:  2019-05-09       Impact factor: 2.430

8.  A Dynamic Systems Approach for Detecting and Localizing of Infarct-Related Artery in Acute Myocardial Infarction Using Compressed Paper-Based Electrocardiogram (ECG).

Authors:  Trung Q Le; Vibhuthi Chandra; Kahkashan Afrin; Sanjay Srivatsa; Satish Bukkapatnam
Journal:  Sensors (Basel)       Date:  2020-07-17       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.