Literature DB >> 20464315

Effect of retorque on loosening torque of prosthetic screws under two levels of fit of implant-supported dentures.

Aloísio Oro Spazzin1, Guilherme Elias Pessanha Henrique, Mauro Antônio de Arruda Nóbilo, Rafael Leonardo Xediek Consani, Lourenço Correr-Sobrinho, Marcelo Ferraz Mesquita.   

Abstract

This study evaluated the influence of retorque on loosening torque (Lt) of prosthetic screws in implant-supported dentures with different fit levels. Ten mandibular implant-supported dentures were fabricated and then 20 cast models were then prepared using prosthetic structures to create 2 fit levels: passive fit (Pf) and misfit (Mf). Two tightening techniques were also evaluated: initial torque only (T1); and initial torque and retorque after 10 min (T2). Gold or titanium screws were used, resulting in 4 groups to each one: Pf/T1, Pf/T2, Mf/T1, Mf/T2. The Lt was measured 24 h after the tightening torque using digital torque meter. Data were analyzed statistically by two-way ANOVA and Tukey's test (alpha=0.05), separately for each screw material. For titanium screws, no significant difference (p>0.05) was found between Pf/T1 and Pf/T2, or between Pf/T2 and Mf/T2. However, statistically significant difference (p<0.05) was found between Pf/T1 and Mf/T1, and between Mf/T1 and Mf/T2. Mf reduced the Lt using T1, while and T2 increased the Lt for Mf. Retorque and fit were shown to have no significant influence on the Lt of the gold screws. Retorque application made insignificant the misfit effect on the Lt of the titanium screws, suggesting that this procedure should be performed routinely during the screw tightening in multi-unit dentures.

Mesh:

Substances:

Year:  2010        PMID: 20464315     DOI: 10.1590/s0103-64402010000100002

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  9 in total

1.  In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs.

Authors:  Ana Sofia Vinhas; Carlos Aroso; Filomena Salazar; Marta Relvas; Ana Cristina Braga; Blanca Ríos-Carrasco; Javier Gil; José Vicente Rios-Santos; Ana Fernández-Palacín; Mariano Herrero-Climent
Journal:  Materials (Basel)       Date:  2022-02-14       Impact factor: 3.623

2.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

3.  Correlation between microleakage and screw loosening at implant-abutment connection.

Authors:  Cem Sahin; Simel Ayyildiz
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

4.  Temperature rise during removal of fractured components out of the implant body: an in vitro study comparing two ultrasonic devices and five implant types.

Authors:  Eric W Meisberger; Sjoerd J G Bakker; Marco S Cune
Journal:  Int J Implant Dent       Date:  2015-03-20

5.  Stability of the prosthetic screws of three types of craniofacial prostheses retention systems.

Authors:  Antonio Gabriel Lanata-Flores; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Veber Luiz Bomfim-Azevedo; Sergio Olate; José Ricardo de Albergaria-Barbosa
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-12-27

6.  Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study).

Authors:  Eman Mohammed Nasr Attiah; Attiah Ali AlGendy; Tamer Mohamed Nasr Mostafa
Journal:  Int J Implant Dent       Date:  2020-07-28

7.  A 3-year prospective cohort study on mandibular anterior cantilever restorations associated with screw-retained implant-supported prosthesis: An in vivo study.

Authors:  Vizaikumar Vasudha Nelluri; Kandathilparambil Maria Roseme; Rajani Kumar Gedela
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

8.  Investigating the effect of abutment-implant connection type on abutment screw loosening in a dental implant system using finite element methods.

Authors:  Alireza Pournasrollah; Ramin Negahdari; Vahedeh Gharekhani; Ali Torab; Soheil Jannati Ataei
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019

9.  Mechanical Stability of Screw-Retained Monolithic and Bi-layer Posterior Hybrid Abutment Crowns after Thermomechanical Loading: An In Vitro Study.

Authors:  Frank A Spitznagel; Estevam A Bonfante; Tiago M B Campos; Maximilian A Vollmer; Johannes Boldt; Sam Doerken; Petra C Gierthmuehlen
Journal:  Materials (Basel)       Date:  2021-12-08       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.