Literature DB >> 20462582

A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitro.

E Dall'Ara1, R Schmidt, D Pahr, P Varga, Y Chevalier, J Patsch, F Kainberger, P Zysset.   

Abstract

Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R(2) improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae. 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20462582     DOI: 10.1016/j.jbiomech.2010.04.023

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  25 in total

1.  The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty.

Authors:  Michael Kinzl; Lorin M Benneker; Andreas Boger; Philippe K Zysset; Dieter H Pahr
Journal:  Eur Spine J       Date:  2011-12-15       Impact factor: 3.134

2.  Locally measured microstructural parameters are better associated with vertebral strength than whole bone density.

Authors:  J Hazrati Marangalou; F Eckstein; V Kuhn; K Ito; M Cataldi; F Taddei; B van Rietbergen
Journal:  Osteoporos Int       Date:  2013-12-04       Impact factor: 4.507

Review 3.  Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images.

Authors:  Dieter H Pahr; Philippe K Zysset
Journal:  Curr Osteoporos Rep       Date:  2016-12       Impact factor: 5.096

4.  QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA.

Authors:  E Dall'Ara; D Pahr; P Varga; F Kainberger; P Zysset
Journal:  Osteoporos Int       Date:  2011-02-23       Impact factor: 4.507

5.  Micromechanics of the human vertebral body for forward flexion.

Authors:  Haisheng Yang; Shashank Nawathe; Aaron J Fields; Tony M Keaveny
Journal:  J Biomech       Date:  2012-06-16       Impact factor: 2.712

6.  Peripheral quantitative computed tomography (pQCT)-based finite element analysis provides enhanced diagnostic performance in identifying non-vertebral fracture patients compared with dual-energy X-ray absorptiometry.

Authors:  H Jiang; D L Robinson; C J Yates; P V S Lee; J D Wark
Journal:  Osteoporos Int       Date:  2019-11-13       Impact factor: 4.507

7.  Biomechanical evaluation of an injectable and biodegradable copolymer P(PF-co-CL) in a cadaveric vertebral body defect model.

Authors:  Zhong Fang; Hugo Giambini; Heng Zeng; Jon J Camp; Mahrokh Dadsetan; Richard A Robb; Kai-Nan An; Michael J Yaszemski; Lichun Lu
Journal:  Tissue Eng Part A       Date:  2014-01-10       Impact factor: 3.845

8.  Modelling of bone fracture and strength at different length scales: a review.

Authors:  Fereshteh A Sabet; Ahmad Raeisi Najafi; Elham Hamed; Iwona Jasiuk
Journal:  Interface Focus       Date:  2016-02-06       Impact factor: 3.906

9.  Assessment of vertebral wedge strength using cancellous textural properties derived from digital tomosynthesis and density properties from dual energy X-ray absorptiometry and high resolution computed tomography.

Authors:  Yener N Yeni; Woong Kim; Daniel Oravec; Mary Nixon; George W Divine; Michael J Flynn
Journal:  J Biomech       Date:  2018-08-22       Impact factor: 2.712

10.  Finite element analysis for prediction of bone strength.

Authors:  Philippe K Zysset; Enrico Dall'ara; Peter Varga; Dieter H Pahr
Journal:  Bonekey Rep       Date:  2013-08-07
View more