Literature DB >> 20460067

Impact of talar component rotation on contact pressure after total ankle arthroplasty: a cadaveric study.

Tomiko Fukuda1, Steven L Haddad, Yupeng Ren, Li-Qun Zhang.   

Abstract

BACKGROUND: There is limited literature available to assess the impact of talar component rotation on total ankle contact biomechanics.
MATERIALS AND METHODS: Six male cadaveric below-knee specimens were implanted with Agility(R) total ankles. The sequence of talar rotation for each specimen was randomized between: Neutral, 7.5 degrees internal and 7.5 degrees external rotation. Contact pressure was measured using Tekscan ankle sensors during sequential static axial loadings and 10 simulated dynamic strides under 650 N axial load.
RESULTS: The peak pressure (PP) increased for the internally (PP(static)=7.0 +/- 0.27 MPa (mean +/- SD), p < 0.001; PP(dynamic)=7.8 +/- 0.22 MPa, p = 0.001) and externally rotated talar component positions (PP(static)=6.2 +/- 0.22 MPa, p = 0.011; PP(dynamic)=7.6 +/- 0.29 MPa, p = 0.004) as compared to neutral (PP(static) =5.5 +/- 0.13 MPa; PP(dynamic) = 6.3 +/- 0.11 MPa). The contact area under 650 approximately N load was reduced for both talar component internal (97.38 +/- 17.7 mm(2), p = 0.001) and external rotation (152.66 +/- 16.8 mm(2), p = 0.022) as compared to neutral (190.02 +/- 13.8 mm(2)). There was a significant rotational torque for the malrotated talar components as compared to neutral, that increased with axial loading (p = 0.044).
CONCLUSION: Near the extremes of talar malrotation, there was a consistent change from a continuous tibiotalar contact area to a pattern of two-point contact; the orientation of which opposed the direction of talar component malrotation. Talar component malrotation resulted in: increased peak pressure, decreased contact area and increased rotational torque that resisted the malrotation. CLINICAL RELEVANCE: Talar component malrotation may contribute to premature polyethylene wear as well as potential talar loosening secondary to the rotational torque generated as the geometry of the prosthesis attempts to seek congruency.

Entities:  

Mesh:

Year:  2010        PMID: 20460067     DOI: 10.3113/FAI.2010.0404

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  8 in total

Review 1.  Total ankle replacement.

Authors:  Alexej Barg; Matthias D Wimmer; Martin Wiewiorski; Dieter C Wirtz; Geert I Pagenstert; Victor Valderrabano
Journal:  Dtsch Arztebl Int       Date:  2015-03-13       Impact factor: 5.594

2.  Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review.

Authors:  Qiuyuan Wang; Nianfei Zhang; Wanshou Guo; Weiguo Wang; Qidong Zhang
Journal:  Int Orthop       Date:  2021-08-04       Impact factor: 3.075

3.  Sagittal Tibiotalar Alignment May Not Affect Functional Outcomes in Fixed-Bearing Total Ankle Replacement: A Retrospective Cohort Study.

Authors:  Natalie M Nielsen; Guilherme H Saito; Austin E Sanders; Scott J Ellis; Carolyn M Sofka; Constantine A Demetracopoulos
Journal:  HSS J       Date:  2019-11-22

4.  Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement.

Authors:  Matthias Braito; Michael Liebensteiner; Dietmar Dammerer; Martin Krismer; Martin Pfurner; Rainer Biedermann
Journal:  J Orthop Surg Res       Date:  2015-05-20       Impact factor: 2.359

5.  Accuracy assessment of measuring component position after total ankle arthroplasty using a conventional method.

Authors:  Kyoung-Jai Lee; Shao-Hua Wang; Gun-Woo Lee; Keun-Bae Lee
Journal:  J Orthop Surg Res       Date:  2017-07-31       Impact factor: 2.359

6.  Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot.

Authors:  Yan Wang; Zengyong Li; Duo Wai-Chi Wong; Cheng-Kung Cheng; Ming Zhang
Journal:  J Orthop Translat       Date:  2017-12-30       Impact factor: 5.191

7.  A new ligament-compatible patient-specific 3D-printed implant and instrumentation for total ankle arthroplasty: from biomechanical studies to clinical cases.

Authors:  C Faldini; A Mazzotti; C Belvedere; G Durastanti; A Panciera; G Geraci; A Leardini
Journal:  J Orthop Traumatol       Date:  2020-09-02

8.  What Are the Indications for Implant Revision in Three-component Total Ankle Arthroplasty?

Authors:  Daniel Richter; Nicola Krähenbühl; Roman Susdorf; Alexej Barg; Roxa Ruiz; Beat Hintermann
Journal:  Clin Orthop Relat Res       Date:  2021-03-01       Impact factor: 4.755

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.