Literature DB >> 20457369

Objective analysis of toric intraocular lens rotation and centration.

James S Wolffsohn1, Phillip J Buckhurst.   

Abstract

PURPOSE: To assess the repeatability of an objective image-analysis technique to determine intraocular lens (IOL) rotation and centration.
SETTING: Six European ophthalmology clinics.
METHODS: Eyes with an Akreos AO aspheric IOL with orientation marks were imaged. A masked observer rated image quality. The axis of rotation was determined from a line bisecting the IOL orientation marks. This was normalized for rotation of the eye between visits using the axis bisecting 2 consistent conjunctival vessels or iris features. The center of ovals overlaid to circumscribe the IOL optic edge and the pupil or limbus were compared to determine IOL centration. Intrasession repeatability was assessed in a subgroup of eyes and the variability of repeated analysis examined.
RESULTS: The SD of intrasession repeatability was +/-0.79 degrees for IOL rotational stability, +/-0.10 mm for horizontal centration, and +/-0.10 mm for vertical centration. The SD of repeated-analysis variability of the same image was +/-0.70 degrees, +/-0.20 mm, and +/-0.31 mm, respectively. The mean eye rotation (absolute) between visits was 2.23 degrees +/- 1.84 (SD) (10% >5 degrees rotation) using 1 set of consistent conjunctival vessels or iris features and 2.03 +/- 1.66 degrees (7%>5 degrees rotation) using the mean of 2 sets (P = .13). Poorer image quality resulted in larger apparent absolute IOL rotation (r = -0.45, P<.001).
CONCLUSIONS: Objective analysis of digital retroillumination images allowed sensitive assessment of IOL rotation and centration stability. Eye rotation between images can lead to significant errors if not taken into account. Image quality is important to analysis accuracy. (c) 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20457369     DOI: 10.1016/j.jcrs.2009.12.027

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

1.  Early clinical outcome with a new monofocal microincision intraocular lens.

Authors:  Baha Toygar; Ozge Yabas Kiziloglu; Okan Toygar; Ali Murat Hacimustafaoglu
Journal:  Int Ophthalmol       Date:  2016-01-16       Impact factor: 2.031

Review 2.  A review of femtosecond laser assisted cataract surgery for Hawai'i.

Authors:  Ming Chen
Journal:  Hawaii J Med Public Health       Date:  2013-05

3.  Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL: a 1.5-year follow-up.

Authors:  Balázs Gyöngyössy; Paul Jirak; Ulrich Schönherr
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

4.  Simple and accurate alignment of toric intraocular lenses and evaluation of their rotation errors using anterior segment optical coherence tomography.

Authors:  Kazuhiro Watanabe; Kazuno Negishi; Hidemasa Torii; Megumi Saiki; Murat Dogru; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2011-10-29       Impact factor: 2.447

5.  Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism.

Authors:  Merve Bozkurt Gencer; Hikmet Basmak; Erdogan Yasar; Ozkan Onal
Journal:  Int J Ophthalmol       Date:  2021-12-18       Impact factor: 1.779

6.  Analysis of internal astigmatism and higher order aberrations in eyes implanted with a new diffractive multifocal toric intraocular lens.

Authors:  Peter Mojzis; David P Piñero; Vera Ctvrteckova; Iva Rydlova
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-05-17       Impact factor: 3.117

7.  Femtosecond laser-assisted cataract surgery: a current review.

Authors:  Majid Moshirfar; Daniel S Churgin; Maylon Hsu
Journal:  Middle East Afr J Ophthalmol       Date:  2011-10

Review 8.  A Comparison of Different Operating Systems for Femtosecond Lasers in Cataract Surgery.

Authors:  B M Wu; G P Williams; A Tan; J S Mehta
Journal:  J Ophthalmol       Date:  2015-09-21       Impact factor: 1.909

9.  Rotational stability of a new multicomponent intraocular lens.

Authors:  Harvey S Uy; Carolina Tesone-Coelho
Journal:  Clin Ophthalmol       Date:  2019-09-26

10.  Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista).

Authors:  Mark Packer; Luther Fry; Kevin T Lavery; Robert Lehmann; James McDonald; Louis Nichamin; Brian Bearie; Jon Hayashida; Griffith E Altmann; Omid Khodai
Journal:  Clin Ophthalmol       Date:  2013-09-24
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.