Literature DB >> 20456643

The road to right ventricular septal pacing: techniques and tools.

Harry G Mond1.   

Abstract

Prolonged right ventricular (RV) apical pacing is associated with progressive left ventricular dysfunction due to dysynchronous ventricular activation and contraction. RV septal pacing allows a narrower QRS compared to RV apical pacing, which might reflect a more physiological and synchronous ventricular activation. Previous clinical studies, which did not consistently achieve RV septal pacing, were not confirmatory and need to be repeated. This review summarizes the anatomy of the RV septum, the radiographic appearances of pacing leads in the RV, the electrocardiograph correlates of RV septal lead positioning, and the techniques and tools required for implantation of an active-fixation lead onto the RV septum. Using the described techniques and tools, conventional active-fixation leads can now be reliably secured to either the RV outflow tract septum or mid-RV septum with very low complication rates and good long-term performance. Even though physiologic and hemodynamic studies on true RV septal pacing have not been completed, the detrimental effects of long-term RV apical pacing are significant enough to suggest that it is now time to leave the RV apex and secure all RV leads onto the septum.

Entities:  

Mesh:

Year:  2010        PMID: 20456643     DOI: 10.1111/j.1540-8159.2010.02777.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  12 in total

1.  Electrocardiography findings in right ventricular apical pacing.

Authors:  Xiayan Shen; Ching-Hui Sia; Kian-Keong Poh; Weiting Huang; Kah Leng Ho
Journal:  Singapore Med J       Date:  2020-10       Impact factor: 1.858

2.  Classical fluoroscopy criteria poorly predict right ventricular lead septal positioning by comparison with echocardiography.

Authors:  Fabien Squara; Didier Scarlatti; Philippe Riccini; Gauthier Garret; Pamela Moceri; Emile Ferrari
Journal:  J Interv Card Electrophysiol       Date:  2018-03-13       Impact factor: 1.900

Review 3.  Beware of the coronary arteries with implantable cardiac electronic devices.

Authors:  S Serge Barold; Benjamin J Pang; Harry G Mond
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-09

4.  Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety.

Authors:  Yuan-Hong Liang; Lie Liu; Dong-Li Chen; Chun-Ying Lin; Hong-Wen Fei; Si-Lin Chen; Shu-Lin Wu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2015-12-16

5.  Regional Mechanical Changes Assessed by 2D Speckle-Tracking Longitudinal Strain do not Parallel Electrical Post-Pacing Cardiac Memory.

Authors:  Suran Maria-Claudia-Berenice; Margulescu Andrei-Dumitru; Bruja Ramona; Siliste Calin; Vinereanu Dragos
Journal:  Maedica (Bucur)       Date:  2018-09

6.  Medium-term effects of septal and apical pacing in pacemaker-dependent patients: a double-blind prospective randomized study.

Authors:  Luis Molina; Richard Sutton; William Gandoy; Nicolás Reyes; Susano Lara; Froylán Limón; Susana Gómez; Consuelo Orihuela; Latife Salame; Gabriela Moreno
Journal:  Pacing Clin Electrophysiol       Date:  2013-09-02       Impact factor: 1.976

7.  Marked ST-segment elevation during permanent pacemaker implantation.

Authors:  Tomoyuki Tobushi; Soichiro Kashihara; Toshiaki Kadokami
Journal:  Clin Case Rep       Date:  2016-09-08

8.  Functional characteristics of left ventricular synchronization via right ventricular outflow-tract pacing detected by two-dimensional strain echocardiography.

Authors:  Yasutaka Hirayama; Yuichiro Kawamura; Nobuyuki Sato; Tatsuya Saito; Hideichi Tanaka; Yasuaki Saijo; Kenjiro Kikuchi; Katsumi Ohori; Naoyuki Hasebe
Journal:  J Arrhythm       Date:  2016-06-24

9.  A randomized comparison of fluoroscopic techniques for implanting pacemaker lead on the right ventricular outflow tract septum.

Authors:  Dongli Chen; Huiqiang Wei; Jiaojiao Tang; Lie Liu; Shulin Wu; Chunying Lin; Qianhuan Zhang; Yuanhong Liang; Silin Chen
Journal:  Int J Cardiovasc Imaging       Date:  2016-01-21       Impact factor: 2.357

10.  Real-time echocardiographic guidance for confirming septal placement of right ventricular leads: A pilot study.

Authors:  Manshu Yan; Tahmeed Contractor; Elyse Guran; Melissa McCabe; Uoo Kim
Journal:  J Arrhythm       Date:  2021-05-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.