Literature DB >> 30568738

Regional Mechanical Changes Assessed by 2D Speckle-Tracking Longitudinal Strain do not Parallel Electrical Post-Pacing Cardiac Memory.

Suran Maria-Claudia-Berenice1, Margulescu Andrei-Dumitru1, Bruja Ramona2, Siliste Calin1, Vinereanu Dragos1.   

Abstract

BACKGROUND: Cardiac memory (CM) refers to persistent T-wave changes that appear after cessation of a period of abnormal ventricular activation, such as ventricular pacing. Prior animal studies using tagged magnetic resonance imaging have suggested that CM is associated with prolonged action potential duration and increased strain of late-activated myocardial segments.
OBJECTIVE: The aim of the present study is to determine whether CM induced by ventricular pacing in human subjects is accompanied by regional mechanical changes in late-activated myocardial segments, assessed by left ventricular (LV) longitudinal strain (peak LS) and time-to-peak longitudinal strain (TTP-LS), using 2D-speckle tracking echocardiography (2DSE).
MATERIAL AND METHODS: We included 20 patients (16 women, age 71±11 years), with DDD pacemakers and with normal AV conduction and QRS/T morphology at baseline. CM was induced by DDD pacing with a short AV delay. ECGs and 2DSE were performed before pacing (baseline), at peak CM (immediately after two weeks of pacing), and at CM washout (4 weeks after cessation of pacing). We measured by echocardiography: left ventricular (LV) ejection fraction, LV diastolic function (E, A, E/E'), peak LS and TTP-LS for the earliest (i.e. adjacent to the pacing site) and latest (i.e. latest-activated during ventricular pacing) segments, using an 18-segment LV model.
RESULTS: All patients had electrical (ECG) CM changes, which disappeared by CM washout. LV global systolic and diastolic functions, as well as regional LS (peak LS for both the latest and earliest activated segments) were similar between evaluations. TTP for the latest and earliest activated segments, as well as mean TTP-LS, increased from baseline to peak CM, but did not decrease at CM washout. The dispersion of TTP-LS was not changed.
CONCLUSION: These results suggest that regional mechanical changes, as can be assessed by 2DSE longitudinal strain, do not overlap electrical CM.

Entities:  

Year:  2018        PMID: 30568738      PMCID: PMC6290181          DOI: 10.26574/maedica.2018.13.3.189

Source DB:  PubMed          Journal:  Maedica (Bucur)        ISSN: 1841-9038


  17 in total

Review 1.  Cardiac memory: mechanisms and clinical implications.

Authors:  Kornelis W Patberg; Alexei Shvilkin; Alexei N Plotnikov; Parag Chandra; Mark E Josephson; Michael R Rosen
Journal:  Heart Rhythm       Date:  2005-12       Impact factor: 6.343

2.  Pacemaker stress echocardiography predicts cardiac events in patients with permanent pacemaker.

Authors:  Elena Biagini; Arend F L Schinkel; Abdou Elhendy; Jeroen J Bax; Vittoria Rizzello; Ron T van Domburg; Boudewijn J Krenning; Olaf Schouten; Angelo Branzi; Guido Rocchi; Maarten L Simoons; Don Poldermans
Journal:  Am J Med       Date:  2005-12       Impact factor: 4.965

3.  Mechanoelectrical feedback as novel mechanism of cardiac electrical remodeling.

Authors:  Darwin Jeyaraj; Lance D Wilson; Jia Zhong; Chris Flask; Jeffrey E Saffitz; Isabelle Deschênes; Xin Yu; David S Rosenbaum
Journal:  Circulation       Date:  2007-06-11       Impact factor: 29.690

4.  Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging.

Authors:  Roberto M Lang; Luigi P Badano; Victor Mor-Avi; Jonathan Afilalo; Anderson Armstrong; Laura Ernande; Frank A Flachskampf; Elyse Foster; Steven A Goldstein; Tatiana Kuznetsova; Patrizio Lancellotti; Denisa Muraru; Michael H Picard; Ernst R Rietzschel; Lawrence Rudski; Kirk T Spencer; Wendy Tsang; Jens-Uwe Voigt
Journal:  J Am Soc Echocardiogr       Date:  2015-01       Impact factor: 5.251

Review 5.  A Test in Context: Myocardial Strain Measured by Speckle-Tracking Echocardiography.

Authors:  Patrick Collier; Dermot Phelan; Allan Klein
Journal:  J Am Coll Cardiol       Date:  2017-02-28       Impact factor: 24.094

6.  Reliability and feasibility of longitudinal AFI global and segmental strain compared with 2D left ventricular volumes and ejection fraction: intra- and inter-operator, test-retest, and inter-cycle reproducibility.

Authors:  Paolo Barbier; Oana Mirea; Claudia Cefalù; Anna Maltagliati; Gabriele Savioli; Marco Guglielmo
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-01-05       Impact factor: 6.875

7.  Head-to-Head Comparison of Global and Regional Two-Dimensional Speckle Tracking Strain Versus Cardiac Magnetic Resonance Tagging in a Multicenter Validation Study.

Authors:  Mihaela Silvia Amzulescu; Hélène Langet; Eric Saloux; Alain Manrique; Laurianne Boileau; Alisson Slimani; Pascal Allain; Clotilde Roy; Christophe de Meester; Agnès Pasquet; Mathieu De Craene; David Vancraeynest; Anne-Catherine Pouleur; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Circ Cardiovasc Imaging       Date:  2017-11       Impact factor: 7.792

8.  Accuracy of fluoroscopic and electrocardiographic criteria for pacemaker lead implantation by comparison with three-dimensional echocardiography.

Authors:  Andrei D Mǎrgulescu; Berenice M Suran; Roxana C Rimbaş; Raluca E Dulgheru; Cǎlin Silişte; Dragoş Vinereanu
Journal:  J Am Soc Echocardiogr       Date:  2012-05-19       Impact factor: 5.251

9.  The insufficiency of left anterior oblique and the usefulness of right anterior oblique projection for correct localization of a computed tomography-verified right ventricular lead into the midseptum.

Authors:  Pavel Osmancik; Petr Stros; Dalibor Herman; Karol Curila; Robert Petr
Journal:  Circ Arrhythm Electrophysiol       Date:  2013-06-06

10.  Diagnostic capability and reproducibility of strain by Doppler and by speckle tracking in patients with acute myocardial infarction.

Authors:  Benthe Sjøli; Stein Ørn; Bjørnar Grenne; Halfdan Ihlen; Thor Edvardsen; Harald Brunvand
Journal:  JACC Cardiovasc Imaging       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.