Literature DB >> 20453571

[Gluteal subcutaneous fat thickness measured by computed tomography as an estimate of proper gluteal intramuscular injections in Korean adults].

Gaeul Joo1, Kyeong-Yae Sohng.   

Abstract

PURPOSE: To study the thickness of gluteal subcutaneous fat (SCF) and propose an adequate length for needle for gluteal intramuscular injections based on computed tomography (CT) measurements.
METHODS: The thickness of gluteal SCF were measured and studied for 568 patients who visited a tertiary hospital in Seoul, Korea between January 2007 and February 2009 for routine health screening and who had abdominopelvic CT.
RESULTS: The average thickness of gluteal SCF was 15.92+/-4.08 mm in males and 24.90+/-5.47 mm in females. The thickness of gluteal SCF differed significantly according to gender. The gluteal SCF thickness was greater than 20.4 mm for 54 (12.3%) of the 440 male patients and 99 (77.3%) of the 128 female patients.
CONCLUSION: The most common syringe needle used for gluteal intramuscular injections in Korea is a 23 G, 25.4 mm-needle. The SCF thickness must be less than 20.4 mm in order to reach the dorsogluteal muscles to a depth of at least 5 mm if this 25.4 mm needle is used. In many patients, especially in female patients, the 25.4 mm needles will result in improper intramuscular injections with the injection being into the SCF. Therefore an appropriate needle should be selected by considering the gender and SCF thickness of patients receiving gluteal intramuscular injections.

Entities:  

Mesh:

Year:  2010        PMID: 20453571     DOI: 10.4040/jkan.2010.40.2.247

Source DB:  PubMed          Journal:  J Korean Acad Nurs        ISSN: 2005-3673            Impact factor:   0.984


  3 in total

1.  The appropriateness of the length of insulin needles based on determination of skin and subcutaneous fat thickness in the abdomen and upper arm in patients with type 2 diabetes.

Authors:  Kang Hee Sim; Moon Sook Hwang; Sun Young Kim; Hye Mi Lee; Ji Yeun Chang; Moon Kyu Lee
Journal:  Diabetes Metab J       Date:  2014-04-18       Impact factor: 5.376

2.  Comment on the New Indian Injection Technique Recommendations: Critical Appraisal of the Real-World Implementation of the Current Guidelines.

Authors:  Felice Strollo; Sandro Gentile
Journal:  Diabetes Ther       Date:  2017-04-26       Impact factor: 2.945

3.  Analysis of gluteal subcutaneous and muscle thickness in infants and children for application to intramuscular injection, autologous fat grafting, and gluteal artery perforator flaps.

Authors:  Hyung Jun Min; Yu Jin Kim
Journal:  Arch Plast Surg       Date:  2018-11-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.