Literature DB >> 20452601

Characterization of new types of stationary phases for fast and ultra-fast liquid chromatography by signal processing based on AutoCovariance Function: a case study of application to Passiflora incarnata L. extract separations.

Maria Chiara Pietrogrande1, Francesco Dondi, Alessia Ciogli, Francesco Gasparrini, Antonella Piccin, Mauro Serafini.   

Abstract

In this study, a comparative investigation was performed of HPLC Ascentis (2.7 microm particles) columns based on fused-core particle technology and Acquity (1.7 microm particles) columns requiring UPLC instruments, in comparison with Chromolith RP-18e columns. The study was carried out on mother and vegetal tinctures of Passiflora incarnata L. on one single or two coupled columns. The fundamental attributions of the chromatographic profiles are evaluated using a chemometric procedure, based on the AutoCovariance Function (ACVF). Different chromatographic systems are compared in terms of their separation parameters, i.e., number of total chemical components (m(tot)), separation efficiency (sigma), peak capacity (n(c)), overlap degree of peaks and peak purity. The obtained results show the improvements achieved by HPLC columns with narrow size particles in terms of total analysis time and chromatographic efficiency: comparable performance are achieved by Ascentis (2.7 microm particle) column and Acquity (1.7 microm particle) column requiring UPLC instruments. The ACVF plot is proposed as a simplified tool describing the chromatographic fingerprint to be used for evaluating and comparing chemical composition of plant extracts by using the parameters D% - relative abundance of the deterministic component - and c(EACF) - similarity index computed on ACVF. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20452601     DOI: 10.1016/j.chroma.2010.04.048

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  A critical quality parameter in quantitative fused-core chromatography: The injection volume.

Authors:  Jente Boonen; Matthias D'hondt; Lieselotte Veryser; Kathelijne Peremans; Christian Burvenich; Bart De Spiegeleer
Journal:  J Pharm Anal       Date:  2013-02-17

Review 2.  Silica-Based Monolithic Columns as a Tool in HPLC-An Overview of Application in Analysis of Active Compounds in Biological Samples.

Authors:  Michał Staniak; Magdalena Wójciak; Ireneusz Sowa; Katarzyna Tyszczuk-Rotko; Maciej Strzemski; Sławomir Dresler; Wojciech Myśliński
Journal:  Molecules       Date:  2020-07-09       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.