Literature DB >> 20452177

Is the anterior tibial tuberosity a reliable rotational landmark for the tibial component in total knee arthroplasty?

Michel P Bonnin1, Mohammed Saffarini, Pierre-Etienne Mercier, Jean-Raphael Laurent, Yannick Carrillon.   

Abstract

To analyze the morphology of the tibial plateau, we studied 100 computed tomographic scans of arthritic knees and measured the mediolateral (ML) and anteroposterior (AP) dimensions as well as their aspect ratio using 3 reference axes of rotation: transepicondylar axis (TEA), posterior tibial margin (PTM), and anterior tibial tuberosity (ATT) axis. Relative to the TEA, the PTM was internally rotated by 1.6° ± 5.1°, and the ATT externally rotated by 14.8° ± 7.2°. The AP and ML dimensions and aspect ratio differ significantly when the reference axis was ATT compared with PTM or TEA and variations were greater while using ATT axis. Our data demonstrate (1) that design of the tibial component restricts the choice of rotational alignment and (2) that ATT is not a reliable landmark for rotation of the tibial component.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20452177     DOI: 10.1016/j.arth.2010.03.015

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  20 in total

1.  Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Alfonso Noriega-Fernandez; Jose Manuel Fernandez-Carreira; Jose Manuel Fernandez-Simon; Jimena Llorens de los Rios
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

2.  Normal Femorotibial Rotational Alignment and Implications for Total Knee Arthroplasty: an MRI Analysis.

Authors:  Gregory C Wernecke; Ian A Harrris; Bradley G Seeto; Darren B Chen; Samuel J MacDessi
Journal:  HSS J       Date:  2016-02-22

3.  Rotational limb alignment changes following total knee arthroplasty.

Authors:  Oliver Hauschild; Matthias Muenzberg; Dagmar Knothe; Lukas Konstantinidis; Peter Helwig; Norbert P Sudkamp; Friedrich W Thielemann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-28       Impact factor: 4.342

4.  Maximizing tibial coverage is detrimental to proper rotational alignment.

Authors:  Stacey Martin; Alex Saurez; Sabir Ismaily; Kashif Ashfaq; Philip Noble; Stephen J Incavo
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

5.  Tibial torsion among filipinos: a cadaveric study.

Authors:  Cac Villamin; Jfc Syquia
Journal:  Malays Orthop J       Date:  2012-11

6.  Influence of tibial rotation in total knee arthroplasty on knee kinematics and retropatellar pressure: an in vitro study.

Authors:  Arnd Steinbrück; Christian Schröder; Matthias Woiczinski; Tatjana Müller; Peter E Müller; Volkmar Jansson; Andreas Fottner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-11       Impact factor: 4.342

7.  Oversizing the tibial component in TKAs: incidence, consequences and risk factors.

Authors:  Michel P Bonnin; Mo Saffarini; David Shepherd; Nadine Bossard; Emmanuelle Dantony
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-21       Impact factor: 4.342

Review 8.  Considerable inter-individual variability of tibial geometric ratios renders bone-implant mismatch unavoidable using off-the-shelf total knee arthroplasty: a systematic review and meta-analysis.

Authors:  Lucas Beckers; Jacobus H Müller; Jeremy Daxhelet; Salvatore Ratano; Mo Saffarini; Tarik Aït-Si-Selmi; Michel P Bonnin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-06-01       Impact factor: 4.342

9.  Promising early outcomes of a novel anatomic knee system.

Authors:  Vincent P Galea; Mina A Botros; Rami Madanat; Christian S Nielsen; Charles Bragdon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-25       Impact factor: 4.342

10.  Total knee replacement modifies the preoperative tibial torsion angle-similar results between computer-assisted and standard technique.

Authors:  Daniel Hernandez-Vaquero; Alfonso Noriega-Fernandez; Sergio Roncero-Gonzalez; Andres A Sierra-Pereira; Manuel A Sandoval-Garcia
Journal:  Ann Transl Med       Date:  2018-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.