Literature DB >> 20449896

Noninvasive blood pressure measurement by the Nexfin monitor during reduced arterial pulsatility: a feasibility study.

Jerson R Martina1, Berend E Westerhof, Jeroen Van Goudoever, Nicolaas De Jonge, Johannes J Van Lieshout, Jaap R Lahpor, Bas A J M De Mol.   

Abstract

Noninvasive blood pressure measurements are difficult when arterial pulsations are reduced, as in patients supported by continuous flow left ventricular assist devices (cf-LVAD). We evaluated the feasibility of measuring noninvasive arterial blood pressure with the Nexfin monitor during conditions of reduced arterial pulsatility. During cardiopulmonary bypass(CPB) in which a roller pump based or a centrifugal pump based heart-lung machine generated arterial blood pressure with low pulsatility, noninvasive arterial pressures (NAP)measured by the Nexfin Monitor were recorded and compared with invasively measured radial artery pressures (IAP).We also evaluated NAP in 10 patients with a cf-LVAD during a pump speed change procedure (PSCP). During CPB in 18 patients, the NAP-IAP average difference was -1.3 +/- 6.5 mmHg. The amplitude of pressure oscillations were 4.3 +/- 3.8 mmHg measured by IAP. Furthermore, in the cf-LVAD patients, increase in pump speed settings led to an increase in diastolic and mean arterial pressures (MAP) while the NAP acquired a sinusoidal shape as the aortic valve become permanently closed. In conclusion, NAP was similar to IAP under conditions of reduced arterial pulsatility. The device also measured the blood pressure waveform noninvasively in patients supported by a cf-LVAD.

Entities:  

Mesh:

Year:  2010        PMID: 20449896     DOI: 10.1097/mat.0b013e3181d70227

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  12 in total

Review 1.  [Intensive care treatment of patients with left ventricular assist devices].

Authors:  B Steinlechner; Daniel Zimpfer; Arno Schiferer; Nikolaus Heinrich; Thomas Schlöglhofer; Angela Rajek; Martin Dworschak; Michael Hiesmayr
Journal:  Med Klin Intensivmed Notfmed       Date:  2015-08-28       Impact factor: 0.840

2.  Noninvasive assessment of hemodynamics: a comparative analysis of fingertip pulse contour analysis and impedance cardiography.

Authors:  Katherine A Sauder; Paige E Pokorney; Cindy E McCrea; Jan S Ulbrecht; Penny M Kris-Etherton; Sheila G West
Journal:  Blood Press Monit       Date:  2015-08       Impact factor: 1.444

Review 3.  Smartphone Applications for Hypertension Management: a Potential Game-Changer That Needs More Control.

Authors:  Gianfranco Parati; Camilla Torlasco; Stefano Omboni; Dario Pellegrini
Journal:  Curr Hypertens Rep       Date:  2017-06       Impact factor: 5.369

Review 4.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

5.  Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

Authors:  Guo Chen; Elena Chung; Lingzhong Meng; Brenton Alexander; Trung Vu; Joseph Rinehart; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2012-03-01       Impact factor: 2.502

6.  Cardiac parameters in children recovered from acute illness as measured by electrical cardiometry and comparisons to the literature.

Authors:  Jackson Wong; Michael S D Agus; Garry M Steil
Journal:  J Clin Monit Comput       Date:  2012-10-06       Impact factor: 2.502

Review 7.  A practical guide to active stand testing and analysis using continuous beat-to-beat non-invasive blood pressure monitoring.

Authors:  Ciarán Finucane; V K van Wijnen; C W Fan; C Soraghan; L Byrne; B E Westerhof; R Freeman; A Fedorowski; M P M Harms; W Wieling; R Kenny
Journal:  Clin Auton Res       Date:  2019-05-10       Impact factor: 4.435

Review 8.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

9.  Non-invasive assessment of cardiac hemodynamics in patients with advanced cancer and with chronic heart failure: a pilot feasibility study.

Authors:  Stephan von Haehling; Mitja Lainscak; Thomas Kung; Larissa Cramer; Susann Fülster; Uwe Pelzer; Bert Hildebrandt; Anja Sandek; Joerg C Schefold; Mathias Rauchhaus; Wolfram Doehner; Stefan D Anker
Journal:  Arch Med Sci       Date:  2013-04-22       Impact factor: 3.318

10.  Short-Term Cardiovascular Response to Short-Radius Centrifugation With and Without Ergometer Exercise.

Authors:  Ana Diaz-Artiles; Thomas Heldt; Laurence R Young
Journal:  Front Physiol       Date:  2018-11-13       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.