Literature DB >> 20449563

[Results of the Wallis interspinous spacer].

M Reith1, M Richter.   

Abstract

An increasing number of different interspinous devices are being used for different indications. The Wallis interspinous implant was invented in 1986 by Mr. Jacques Sénégas as one of the first modern interspinous devices. The primary intention of Sénégas was to improve segmental stabilisation, based on the unloading of the facet joints and the disc. The Wallis system is easy to handle and the early clinical results are promising. How far the early outcome will lead to good long-term results is unknown, because there are no long-term results in the literature till now. Limiting factors for the devices are the possible biomechanical overload, the loosening of the implants and the lytic zones around the spinous processes after more than 1 year.

Mesh:

Year:  2010        PMID: 20449563     DOI: 10.1007/s00132-009-1590-8

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  14 in total

Review 1.  Lumbar disc degeneration: epidemiology and genetic influences.

Authors:  Michele C Battié; Tapio Videman; Eric Parent
Journal:  Spine (Phila Pa 1976)       Date:  2004-12-01       Impact factor: 3.468

Review 2.  Nutrition of the intervertebral disc.

Authors:  Jill P G Urban; Stanton Smith; Jeremy C T Fairbank
Journal:  Spine (Phila Pa 1976)       Date:  2004-12-01       Impact factor: 3.468

Review 3.  Classification of posterior dynamic stabilization devices.

Authors:  Paul Khoueir; K Anthony Kim; Michael Y Wang
Journal:  Neurosurg Focus       Date:  2007-01-15       Impact factor: 4.047

Review 4.  Interspinous process devices in the lumbar spine.

Authors:  Christopher M Bono; Alexander R Vaccaro
Journal:  J Spinal Disord Tech       Date:  2007-05

5.  Foreign body reaction due to polyethylene's wear after implantation of an interspinal segment.

Authors:  Joerg Jerosch; Mohammed G Moursi
Journal:  Arch Orthop Trauma Surg       Date:  2007-08-23       Impact factor: 3.067

6.  Clinical evaluation of a lumbar interspinous dynamic stabilization device (the Wallis system) with a 13-year mean follow-up.

Authors:  Jacques Sénégas; Jean-Marc Vital; Vincent Pointillart; Paolo Mangione
Journal:  Neurosurg Rev       Date:  2009-04-22       Impact factor: 3.042

7.  Surgical therapy for lumbar spinal stenosis: evaluation of 300 cases.

Authors:  B Cirak; M Alptekin; S Palaoglu; O E Ozcan; T Ozgen
Journal:  Neurosurg Rev       Date:  2001-07       Impact factor: 3.042

8.  The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression.

Authors:  Tobias L Schulte; Christof Hurschler; Marcel Haversath; Ulf Liljenqvist; Viola Bullmann; Timm J Filler; Nani Osada; Eva-Maria Fallenberg; Lars Hackenberg
Journal:  Eur Spine J       Date:  2008-05-21       Impact factor: 3.134

9.  Failure of the Wallis interspinous implant to lower the incidence of recurrent lumbar disc herniations in patients undergoing primary disc excision.

Authors:  Yizhar Floman; Michael A Millgram; Yossi Smorgick; Nahshon Rand; Ely Ashkenazi
Journal:  J Spinal Disord Tech       Date:  2007-07

10.  High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis.

Authors:  Olaf J Verhoof; Johannes L Bron; Frits H Wapstra; Barend J van Royen
Journal:  Eur Spine J       Date:  2007-09-11       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.