Push-pull perfusion sampling with segmented flow for high temporal and spatial resolution in vivo chemical monitoring.

Thomas R Slaney1, Jing Nie, Neil D Hershey, Prasanna K Thwar, Jennifer Linderman, Mark A Burns, Robert T Kennedy.   

Abstract

Low-flow push-pull perfusion is a sampling method that yields better spatial resolution than competitive methods like microdialysis. Because of the low flow rates used (50 nL/min), it is challenging to use this technique at high temporal resolution which requires methods of collecting, manipulating, and analyzing nanoliter samples. High temporal resolution also requires control of Taylor dispersion during sampling. To meet these challenges, push-pull perfusion was coupled with segmented flow to achieve in vivo sampling at 7 s temporal resolution at 50 nL/min flow rates. By further miniaturizing the probe inlet, sampling with 200 ms resolution at 30 nL/min (pull only) was demonstrated in vitro. Using this method, L-glutamate was monitored in the striatum of anesthetized rats. Up to 500 samples of 6 nL each were collected at 7 s intervals, segmented by an immiscible oil and stored in a capillary tube. The samples were assayed offline for L-glutamate at a rate of 15 samples/min by pumping them into a reagent addition tee fabricated from Teflon where reagents were added for a fluorescent enzyme assay. Fluorescence of the resulting plugs was monitored downstream. Microinjection of 70 mM potassium in physiological buffered saline evoked l-glutamate concentration transients that had an average maxima of 4.5 ± 1.1 μM (n = 6 animals, 3-4 injections each) and rise times of 22 ± 2 s. These results demonstrate that low-flow push-pull perfusion with segmented flow can be used for high temporal resolution chemical monitoring and in complex biological environments.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21604670      PMCID: PMC3128237          DOI: 10.1021/ac2003938

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  36 in total

1.  SlipChip for immunoassays in nanoliter volumes.

Authors:  Weishan Liu; Delai Chen; Wenbin Du; Kevin P Nichols; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

Review 2.  Reactions in droplets in microfluidic channels.

Authors:  Helen Song; Delai L Chen; Rustem F Ismagilov
Journal:  Angew Chem Int Ed Engl       Date:  2006-11-13       Impact factor: 15.336

3.  Using a multijunction microfluidic device to inject substrate into an array of preformed plugs without cross-contamination: comparing theory and experiments.

Authors:  Liang Li; James Q Boedicker; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2007-03-06       Impact factor: 6.986

4.  High temporal resolution coupling of low-flow push-pull perfusion to capillary electrophoresis for ascorbate analysis at the rat vitreoretinal interface.

Authors:  Eric E Patterson; Jeanita S Pritchett; Scott A Shippy
Journal:  Analyst       Date:  2008-11-27       Impact factor: 4.616

5.  The electrochemical detection of droplets in microfluidic devices.

Authors:  Shujuan Liu; Yunfeng Gu; Rudolph B Le Roux; Sinéad M Matthews; Daniel Bratton; Kamran Yunus; Adrian C Fisher; Wilhelm T S Huck
Journal:  Lab Chip       Date:  2008-09-19       Impact factor: 6.799

6.  The chemistrode: a droplet-based microfluidic device for stimulation and recording with high temporal, spatial, and chemical resolution.

Authors:  Delai Chen; Wenbin Du; Ying Liu; Weishan Liu; Andrey Kuznetsov; Felipe E Mendez; Louis H Philipson; Rustem F Ismagilov
Journal:  Proc Natl Acad Sci U S A       Date:  2008-10-30       Impact factor: 11.205

7.  Measuring rapid enzymatic kinetics by electrochemical method in droplet-based microfluidic devices with pneumatic valves.

Authors:  Zuoyan Han; Wentao Li; Yanyi Huang; Bo Zheng
Journal:  Anal Chem       Date:  2009-07-15       Impact factor: 6.986

8.  SlipChip.

Authors:  Wenbin Du; Liang Li; Kevin P Nichols; Rustem F Ismagilov
Journal:  Lab Chip       Date:  2009-05-15       Impact factor: 6.799

9.  Improved temporal resolution for in vivo microdialysis by using segmented flow.

Authors:  Meng Wang; Gregory T Roman; Kristin Schultz; Colin Jennings; Robert T Kennedy
Journal:  Anal Chem       Date:  2008-06-12       Impact factor: 6.986

10.  Sampling and electrophoretic analysis of segmented flow streams using virtual walls in a microfluidic device.

Authors:  Gregory T Roman; Meng Wang; Kristin N Shultz; Colin Jennings; Robert T Kennedy
Journal:  Anal Chem       Date:  2008-10-03       Impact factor: 6.986

View more
  31 in total

1.  Mass spectrometry "sensor" for in vivo acetylcholine monitoring.

Authors:  Peng Song; Neil D Hershey; Omar S Mabrouk; Thomas R Slaney; Robert T Kennedy
Journal:  Anal Chem       Date:  2012-05-24       Impact factor: 6.986

Review 2.  Small-volume analysis of cell-cell signaling molecules in the brain.

Authors:  Elena V Romanova; Jordan T Aerts; Callie A Croushore; Jonathan V Sweedler
Journal:  Neuropsychopharmacology       Date:  2013-06-10       Impact factor: 7.853

Review 3.  Electrochemical Analysis of Neurotransmitters.

Authors:  Elizabeth S Bucher; R Mark Wightman
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2015-05-04       Impact factor: 10.745

4.  User-defined local stimulation of live tissue through a movable microfluidic port.

Authors:  Megan A Catterton; Austin F Dunn; Rebecca R Pompano
Journal:  Lab Chip       Date:  2018-07-10       Impact factor: 6.799

5.  Numerical Modeling of Electroosmotic Push-Pull Perfusion and Assessment of Its Application to Quantitative Determination of Enzymatic Activity in the Extracellular Space of Mammalian Tissue.

Authors:  Yangguang Ou; Stephen G Weber
Journal:  Anal Chem       Date:  2017-05-11       Impact factor: 6.986

6.  Assessment of tissue viability following electroosmotic push-pull perfusion from organotypic hippocampal slice cultures.

Authors:  Amy E Rupert; Y Ou; M Sandberg; S G Weber
Journal:  ACS Chem Neurosci       Date:  2013-05-02       Impact factor: 4.418

7.  Electroosmotic push-pull perfusion: description and application to qualitative analysis of the hydrolysis of exogenous galanin in organotypic hippocampal slice cultures.

Authors:  Amy E Rupert; Y Ou; M Sandberg; S G Weber
Journal:  ACS Chem Neurosci       Date:  2013-04-30       Impact factor: 4.418

8.  Microdialysis Coupled with LC-MS/MS for In Vivo Neurochemical Monitoring.

Authors:  Alexander G Zestos; Robert T Kennedy
Journal:  AAPS J       Date:  2017-06-28       Impact factor: 4.009

9.  Stimulation and release from neurons via a dual capillary collection device interfaced to mass spectrometry.

Authors:  Yi Fan; Chang Young Lee; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  Analyst       Date:  2013-11-07       Impact factor: 4.616

10.  Chemical gradients within brain extracellular space measured using low flow push-pull perfusion sampling in vivo.

Authors:  Thomas R Slaney; Omar S Mabrouk; Kirsten A Porter-Stransky; Brandon J Aragona; Robert T Kennedy
Journal:  ACS Chem Neurosci       Date:  2012-11-16       Impact factor: 4.418

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.