Literature DB >> 20446639

Validity and reliability of intra-stroke kayak velocity and acceleration using a GPS-based accelerometer.

Ina Janssen1, Alexi Sachlikidis.   

Abstract

The aim of this study was to assess the validity and reliability of the velocity and acceleration measured by a kayak-mounted GPS-based accelerometer units compared to the video-derived measurements and the effect of satellite configuration on velocity. Four GPS-based accelerometers units of varied accelerometer ranges (2 g or 6 g) were mounted on a kayak as the paddler performed 12 trials at three different stroke rates for each of three different testing sessions (two in the morning vs. one in the afternoon). The velocity and acceleration derived by the accelerometers was compared with the velocity and acceleration derived from high-speed video footage (100Hz). Validity was measured using Bland and Altman plots, R2, and the root of the mean of the squared difference (RMSe), while reliability was calculated using the coefficient of variation, R2, and repeated measures analysis of variance (ANOVA) tests. The GPS-based accelerometers under-reported kayak velocity by 0.14-0.19 m/s and acceleration by 1.67 m/s2 when compared to the video-derived measurements. The afternoon session reported the least difference, indicating a time of day effect on the velocity measured. This study highlights the need for sports utilising GPS-based accelerometers, such as minimaxX, for intra-stroke measurements to conduct sport-specific validity and reliability studies to ensure the accuracy of their data.

Entities:  

Mesh:

Year:  2010        PMID: 20446639     DOI: 10.1080/14763141003690229

Source DB:  PubMed          Journal:  Sports Biomech        ISSN: 1476-3141            Impact factor:   2.832


  7 in total

Review 1.  Sprint Running Performance Monitoring: Methodological and Practical Considerations.

Authors:  Thomas Haugen; Martin Buchheit
Journal:  Sports Med       Date:  2016-05       Impact factor: 11.136

Review 2.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

3.  The inter- and intra-unit variability of a low-cost GPS data logger/receiver to study human outdoor walking in view of health and clinical studies.

Authors:  Pierre Abraham; Bénédicte Noury-Desvaux; Marie Gernigon; Guillaume Mahé; Thomas Sauvaget; Georges Leftheriotis; Alexis Le Faucheur
Journal:  PLoS One       Date:  2012-02-20       Impact factor: 3.240

4.  Identification of cross-country skiing movement patterns using micro-sensors.

Authors:  Finn Marsland; Keith Lyons; Judith Anson; Gordon Waddington; Colin Macintosh; Dale Chapman
Journal:  Sensors (Basel)       Date:  2012-04-18       Impact factor: 3.576

5.  Adaptive smartphone-based sensor fusion for estimating competitive rowing kinematic metrics.

Authors:  Bryn Cloud; Britt Tarien; Ada Liu; Thomas Shedd; Xinfan Lin; Mont Hubbard; R Paul Crawford; Jason K Moore
Journal:  PLoS One       Date:  2019-12-05       Impact factor: 3.240

6.  Acute Oxidative Effect and Muscle Damage after a Maximum 4 Min Test in High Performance Athletes.

Authors:  Heros Ribeiro Ferreira; Pamela Gill Ferreira; João Paulo Loures; José Fernandes Filho; Luiz Cláudio Fernandes; Hudson Sousa Buck; Wagner Ricardo Montor
Journal:  PLoS One       Date:  2016-04-25       Impact factor: 3.240

Review 7.  Technologies That Assess the Location of Physical Activity and Sedentary Behavior: A Systematic Review.

Authors:  Adam Loveday; Lauren B Sherar; James P Sanders; Paul W Sanderson; Dale W Esliger
Journal:  J Med Internet Res       Date:  2015-08-05       Impact factor: 5.428

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.