Literature DB >> 20446037

Finite element shape optimization for biodegradable magnesium alloy stents.

W Wu1, L Petrini, D Gastaldi, T Villa, M Vedani, E Lesma, B Previtali, F Migliavacca.   

Abstract

Biodegradable magnesium alloy stents (MAS) are a promising solution for long-term adverse events caused by interactions between vessels and permanent stent platforms of drug eluting stents. However, the existing MAS showed severe lumen loss after a few months: too short degradation time may be the main reason for this drawback. In this study, a new design concept of MAS was proposed and a shape optimization method with finite element analysis was applied on two-dimensional (2D) stent models considering four different magnesium alloys: AZ80, AZ31, ZM21, and WE43. A morphing procedure was utilized to facilitate the optimization. Two experiments were carried out for a preliminary validation of the 2D models with good results. The optimized designs were compared to an existing MAS by means of three-dimensional finite element analysis. The results showed that the final optimized design with alloy WE43, compared to the existing MAS, has an increased strut width by approximately 48%, improved safety properties (decreased the maximum principal stress after recoil with tissue by 29%, and decreased the maximum principal strain during expansion by 14%) and improved scaffolding ability (increased by 24%). Accordingly, the degradation time can be expected to extend. The used methodology provides a convenient and practical way to develop novel MAS designs.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20446037     DOI: 10.1007/s10439-010-0057-8

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  5 in total

1.  In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy.

Authors:  Chenxin Chen; Jiahui Chen; Wei Wu; Yongjuan Shi; Liang Jin; Lorenza Petrini; Li Shen; Guangyin Yuan; Wenjiang Ding; Junbo Ge; Elazer R Edelman; Francesco Migliavacca
Journal:  Biomaterials       Date:  2019-08-05       Impact factor: 12.479

2.  Optimization of Drug Delivery by Drug-Eluting Stents.

Authors:  Franz Bozsak; David Gonzalez-Rodriguez; Zachary Sternberger; Paul Belitz; Thomas Bewley; Jean-Marc Chomaz; Abdul I Barakat
Journal:  PLoS One       Date:  2015-06-17       Impact factor: 3.240

3.  Computational and experimental mechanical performance of a new everolimus-eluting stent purpose-built for left main interventions.

Authors:  Saurabhi Samant; Wei Wu; Shijia Zhao; Behram Khan; Mohammadali Sharzehee; Anastasios Panagopoulos; Janaki Makadia; Timothy Mickley; Andrew Bicek; Dennis Boismier; Yoshinobu Murasato; Yiannis S Chatzizisis
Journal:  Sci Rep       Date:  2021-04-22       Impact factor: 4.379

4.  Linking the effect of localised pitting corrosion with mechanical integrity of a rare earth magnesium alloy for implant use.

Authors:  Kerstin van Gaalen; Conall Quinn; Felix Benn; Peter E McHugh; Alexander Kopp; Ted J Vaughan
Journal:  Bioact Mater       Date:  2022-08-12

5.  Dual-source computed tomography angiography and intravascular ultrasound assessment of restenosis in patients after coronary stenting for bifurcation left main stenosis: a pilot study.

Authors:  Josef Veselka; Pavla Cadová; Theodor Adla; David Zemánek
Journal:  Arch Med Sci       Date:  2012-07-04       Impact factor: 3.318

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.