Literature DB >> 20443591

Plasma polymerization of maleic anhydride: just what are the right deposition conditions?

Gautam Mishra1, Sally L McArthur.   

Abstract

Maleic anhydride plasma polymers enable amine-containing biomolecules and polymers to be covalently coupled to a surface from an aqueous solution without any intermediate chemistry. The challenge in developing these functionally active plasma polymers lies in determining the optimal deposition conditions for producing a stable, highly active film. Unlike many previous studies that explore highly varied pulsed and continuous wave (CW) deposition conditions, this paper focuses on the comparison of films deposited under the same low nominal power conditions (1 W) and compares a range of CW, millisecond, and microsecond pulsing parameters that can be used to produce this power condition. The use of attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS) has enabled the quantitative examination of the effects of processing parameters on the chemical functionality of the films. For the first time, the molecular specificity, surface sensitivity, and high mass resolution of time-of-flight static secondary ion mass spectrometry (ToF-SSIMS) has been exploited to compare these films and multivariate analysis techniques used to explore the relationships between plasma processing parameters and surface chemistry. The results of the studies clearly demonstrate that a range of conditions can produce maleic anhydride films, with optimal functionality seen under microsecond pulsing regimes. Critically, the study demonstrates that the tight control and monitoring of the deposition parameters is critical if these films are to be manufactured with optimal functionality, stability, and minimum processing time.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20443591      PMCID: PMC2883019          DOI: 10.1021/la100236c

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  9 in total

1.  Modulated fibronectin anchorage at polymer substrates controls angiogenesis.

Authors:  Tilo Pompe; Manuela Markowski; Carsten Werner
Journal:  Tissue Eng       Date:  2004 May-Jun

2.  Observations of Buneman modes as precursory phenomena of a solitary potential pulse.

Authors: 
Journal:  Phys Rev Lett       Date:  1995-03-13       Impact factor: 9.161

3.  Control of attachment of bovine serum albumin to pulse plasma-polymerized maleic anhydride by variation of pulse conditions.

Authors:  Shasha Liu; Margarida M L M Vareiro; Stuart Fraser; A Toby A Jenkins
Journal:  Langmuir       Date:  2005-09-13       Impact factor: 3.882

4.  Non-fouling microfluidic chip produced by radio frequency tetraglyme plasma deposition.

Authors:  Malinda Salim; Gautam Mishra; Gregory J S Fowler; Brian O'sullivan; Phillip C Wright; Sally L McArthur
Journal:  Lab Chip       Date:  2007-02-14       Impact factor: 6.799

5.  Temporal evolution of an electron-free afterglow in the pulsed plasma polymerisation of acrylic acid.

Authors:  Ian Swindells; Sergey A Voronin; Paul M Bryant; Morgan R Alexander; James W Bradley
Journal:  J Phys Chem B       Date:  2008-03-08       Impact factor: 2.991

Review 6.  Organic polymer biocompatibility and toxicology.

Authors:  F Bischoff
Journal:  Clin Chem       Date:  1972-09       Impact factor: 8.327

7.  Covalently immobilized thrombomodulin inhibits coagulation and complement activation of artificial surfaces in vitro.

Authors:  C Sperling; K Salchert; U Streller; C Werner
Journal:  Biomaterials       Date:  2004-09       Impact factor: 12.479

8.  Pulsed plasma polymerized maleic anhydride films in humid air and in aqueous solutions studied with optical waveguide spectroscopy.

Authors:  Li-Qiang Chu; Renate Förch; Wolfgang Knoll
Journal:  Langmuir       Date:  2006-03-14       Impact factor: 3.882

9.  Detection of negative molecular ions in acrylic acid plasma: some implications for polymerization mechanisms.

Authors:  Ian Swindells; Sergey A Voronin; Catalin Fotea; Morgan R Alexander; James W Bradley
Journal:  J Phys Chem B       Date:  2007-07-06       Impact factor: 2.991

  9 in total
  4 in total

Review 1.  Multivariate analysis of ToF-SIMS data from multicomponent systems: the why, when, and how.

Authors:  Daniel J Graham; David G Castner
Journal:  Biointerphases       Date:  2012-08-15       Impact factor: 2.456

2.  Stable low-fouling plasma polymer coatings on polydimethylsiloxane.

Authors:  S Forster; S L McArthur
Journal:  Biomicrofluidics       Date:  2012-09-24       Impact factor: 2.800

3.  Thermally triggered release of the bacteriophage endolysin CHAPK and the bacteriocin lysostaphin for the control of methicillin resistant Staphylococcus aureus (MRSA).

Authors:  Hollie Hathaway; Jude Ajuebor; Liam Stephens; Aidan Coffey; Ursula Potter; J Mark Sutton; A Toby A Jenkins
Journal:  J Control Release       Date:  2016-11-28       Impact factor: 9.776

4.  Confined Crystallization of Thin Plasma-Polymerized Nanocomposite Films with Maleic Anhydride and Cellulose Nanocrystals under Hydrolysis.

Authors:  Pieter Samyn
Journal:  Molecules       Date:  2022-09-03       Impact factor: 4.927

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.