Literature DB >> 20443481

High-quality 3-D coronary artery imaging on an interventional C-arm x-ray system.

Eberhard Hansis1, John D Carroll, Dirk Schäfer, Olaf Dössel, Michael Grass.   

Abstract

PURPOSE: Three-dimensional (3-D) reconstruction of the coronary arteries during a cardiac catheter-based intervention can be performed from a C-arm based rotational x-ray angiography sequence. It can support the diagnosis of coronary artery disease, treatment planning, and intervention guidance. 3-D reconstruction also enables quantitative vessel analysis, including vessel dynamics from a time-series of reconstructions.
METHODS: The strong angular undersampling and motion effects present in gated cardiac reconstruction necessitate the development of special reconstruction methods. This contribution presents a fully automatic method for creating high-quality coronary artery reconstructions. It employs a sparseness-prior based iterative reconstruction technique in combination with projection-based motion compensation.
RESULTS: The method is tested on a dynamic software phantom, assessing reconstruction accuracy with respect to vessel radii and attenuation coefficients. Reconstructions from clinical cases are presented, displaying high contrast, sharpness, and level of detail.
CONCLUSIONS: The presented method enables high-quality 3-D coronary artery imaging on an interventional C-arm system.

Entities:  

Mesh:

Year:  2010        PMID: 20443481     DOI: 10.1118/1.3352869

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Calibration-free device sizing using an inverse geometry x-ray system.

Authors:  Michael T Tomkowiak; Michael A Speidel; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

2.  Local motion-compensated method for high-quality 3D coronary artery reconstruction.

Authors:  Bo Liu; Xiangzhi Bai; Fugen Zhou
Journal:  Biomed Opt Express       Date:  2016-11-23       Impact factor: 3.732

3.  Optimization-based reconstruction of sparse images from few-view projections.

Authors:  Xiao Han; Junguo Bian; Erik L Ritman; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-07-31       Impact factor: 3.609

Review 4.  Multimodality Imaging in Congenital Heart Disease: an Update.

Authors:  Uyen T Truong; Shelby Kutty; Craig S Broberg; David J Sahn
Journal:  Curr Cardiovasc Imaging Rep       Date:  2012
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.