Literature DB >> 20441986

Using ion-pair reversed-phase HPLC ICP-MS to simultaneously determine Cr(III) and Cr(VI) in urine of chromate workers.

Hua-Jian Wang1, Xian-Mei Du, Meng Wang, Tian-Cheng Wang, Hong Ou-Yang, Bing Wang, Mo-Tao Zhu, Yun Wang, Guang Jia, Wei-Yue Feng.   

Abstract

Urinary chromium speciation analysis can provide available information of the individual exposure levels of Cr(VI) compounds. An analytical method based on ion-pair reversed-phase HPLC combined with ICP-MS to simultaneously determine Cr(III) and Cr(VI) in human urine has been developed for assessing the occupational exposure to chromate. The separation conditions of the method, including the pH value, the concentrations of ion-pair reagent and methanol in the mobile phase were studied. Specially, a high-speed polyetheretherketone (PEEK) column and a typical sample introduction method were employed to avoid the exogenous chromium contamination during the analysis. The separation of Cr(III) and Cr(VI) could be finished within 4min with the detection limits as low as 0.03microgL(-1) at 100microL injections for both of them, providing a convenient method for routine analysis of chromium species. The chromium species in urine of chromate workers were monitored using the developed method. The statistical analysis showed a significant relationship (n=32, p<0.01) between the urinary Cr(VI) and the individual airborne exposure levels, indicating that the urinary Cr(VI) could be used as a convenient and suitable monitor for high level Cr(VI) occupational exposure.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20441986     DOI: 10.1016/j.talanta.2010.03.059

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  A cathodic photoelectrochemical sensor for chromium(VI) based on the use of PbS quantum dot semiconductors on an ITO electrode.

Authors:  Panpan Wang; Ling Cao; Ying Wu; Junwei Di
Journal:  Mikrochim Acta       Date:  2018-07-04       Impact factor: 5.833

2.  Renal impairment caused by chronic occupational chromate exposure.

Authors:  Tiancheng Wang; Guang Jia; Ji Zhang; Yanhui Ma; Weiyue Feng; Lanzheng Liu; Ning Zhang; Lei Yan; Xiang Wang; Xueyan Zhang; Zihong Liu; Xianmei Du; Sen Zhen
Journal:  Int Arch Occup Environ Health       Date:  2010-08-18       Impact factor: 3.015

3.  Ultrafast and Energy-saving Synthesis of Nitrogen and Chlorine Co-doped Carbon Nanodots via Neutralization Heat for Selective Detection of Cr(VI) in Aqueous Phase.

Authors:  Qin Hu; Tao Li; Lu Gao; Xiaojuan Gong; Shengqi Rao; Weiming Fang; Ruixia Gu; Zhenquan Yang
Journal:  Sensors (Basel)       Date:  2018-10-11       Impact factor: 3.576

4.  Fluorescent Sensors Based on Organic Polymer-Capped Gold Nanoparticles for the Detection of Cr(VI) in Water.

Authors:  Na Wang; Liangchen Wang; Hong Yang; Tingting Xiong; Shangping Xiao; Jiawen Zhao; Weiping Du
Journal:  Int J Anal Chem       Date:  2019-02-03       Impact factor: 1.885

5.  A New Cr3+ Electrochemical Sensor Based on ATNA/Nafion/Glassy Carbon Electrode.

Authors:  Reda M El-Shishtawy; Mohammed M Rahman; Tahir Ali Sheikh; Muhammad Nadeem Arshad; Fatimah A M Al-Zahrani; Abdullah M Asiri
Journal:  Materials (Basel)       Date:  2020-06-12       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.