Literature DB >> 20436235

Optimal relaxation parameters of DRAMA (dynamic RAMLA) aiming at one-pass image reconstruction for 3D-PET.

Eiichi Tanaka1, Hiroyuki Kudo.   

Abstract

We have reported a block-iterative algorithm named DRAMA for image reconstruction for emission tomography (Tanaka and Kudo 2003 Phys. Med. Biol. 48 1405-22). DRAMA is a modified version of the row-action maximum likelihood algorithm (RAMLA), in which the relaxation parameter is subset dependent and is changed in such a way that the noise propagation from subsets to the reconstructed image is substantially independent of the access order of the subsets. The algorithm provides fast convergence with a reasonable signal-to-noise ratio. The optimal relaxation parameter has been derived assuming a two-dimensional (2D)-PET model, and detailed performance in three-dimensional (3D) reconstruction has not been clear enough. We have developed the new version 'DRAMA-3D', based on the 3D-PET model. The optimal relaxation parameter is a function of the access order of the subsets and the ring difference, and its value is determined by simple formulas from the design parameters of the PET scanner, the operating conditions and the post-smoothing resolution. In this paper, we present the theory of DRAMA-3D, the results of simulation studies on the performance of DRAMA-3D and the comparative studies of the related algorithms. It is shown that DRAMA-3D is robust for various access orders of subsets and is suitable to realize one-pass (single-iteration) reconstruction.

Mesh:

Year:  2010        PMID: 20436235     DOI: 10.1088/0031-9155/55/10/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Performance Evaluation of a Newly Developed MR-Compatible Mobile PET Scanner with Two Detector Layouts.

Authors:  Masao Watanabe; Yuji Nakamoto; Ryusuke Nakamoto; Takayoshi Ishimori; Tsuneo Saga; Kaori Togashi
Journal:  Mol Imaging Biol       Date:  2020-04       Impact factor: 3.488

2.  Investigation of the quantitative accuracy of low-dose amyloid and tau PET imaging.

Authors:  Ying-Hwey Nai; Shoichi Watanuki; Manabu Tashiro; Nobuyuki Okamura; Hiroshi Watabe
Journal:  Radiol Phys Technol       Date:  2018-10-16

3.  Imaging mitochondrial complex I activation during a vibrotactile stimulation: A PET study using [18F]BCPP-EF in the conscious monkey brain.

Authors:  Jingwan Fang; Hiroyuki Ohba; Fumio Hashimoto; Hideo Tsukada; Feiyan Chen; Huafeng Liu
Journal:  J Cereb Blood Flow Metab       Date:  2020-01-16       Impact factor: 6.200

4.  Performance evaluation of dedicated brain PET scanner with motion correction system.

Authors:  Yuya Onishi; Takashi Isobe; Masanori Ito; Fumio Hashimoto; Tomohide Omura; Etsuji Yoshikawa
Journal:  Ann Nucl Med       Date:  2022-06-13       Impact factor: 2.258

5.  Evaluation of D-isomers of 4-borono-2-18F-fluoro-phenylalanine and O-11C-methyl-tyrosine as brain tumor imaging agents: a comparative PET study with their L-isomers in rat brain glioma.

Authors:  Masakatsu Kanazawa; Shingo Nishiyama; Fumio Hashimoto; Takeharu Kakiuchi; Hideo Tsukada
Journal:  EJNMMI Res       Date:  2018-06-13       Impact factor: 3.138

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.