Literature DB >> 20436012

Tribological performance of various CoCr microstructures in metal-on-metal bearings: the development of a more physiological protocol in vitro.

A Kamali1, A Hussain, C Li, J Pamu, J Daniel, H Ziaee, J Daniel, D J W McMinn.   

Abstract

Hip simulators have been used for ten years to determine the tribological performance of large-head metal-on-metal devices using traditional test conditions. However, the hip simulator protocols were originally developed to test metal-on-polyethylene devices. We have used patient activity data to develop a more physiologically relevant test protocol for metal-on-metal devices. This includes stop/start motion, a more appropriate walking frequency, and alternating kinetic and kinematic profiles. There has been considerable discussion about the effect of heat treatments on the wear of metal-on-metal cobalt chromium molybdenum (CoCrMo) devices. Clinical studies have shown a higher rate of wear, levels of metal ions and rates of failure for the heat-treated metal compared to the as-cast metal CoCrMo devices. However, hip simulator studies in vitro under traditional testing conditions have thus far not been able to demonstrate a difference between the wear performance of these implants. Using a physiologically relevant test protocol, we have shown that heat treatment of metal-on-metal CoCrMo devices adversely affects their wear performance and generates significantly higher wear rates and levels of metal ions than in as-cast metal implants.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20436012     DOI: 10.1302/0301-620X.92B5.23320

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 2.  What Factors Drive Taper Corrosion?

Authors:  Robin Pourzal; Hannah J Lundberg; Deborah J Hall; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2018-03-30       Impact factor: 4.757

3.  Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM-F75 alloys.

Authors:  L A Duncan; F H Labeed; M-L Abel; A Kamali; J F Watts
Journal:  J Mater Sci Mater Med       Date:  2011-05-10       Impact factor: 3.896

4.  Metal-on-metal: history, state of the art (2010).

Authors:  Philippe Triclot
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

5.  How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  J Mater Sci Mater Med       Date:  2014-07-12       Impact factor: 3.896

6.  Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions.

Authors:  Robin Pourzal; Deborah J Hall; Jonas Ehrich; Stephanie M McCarthy; Mathew T Mathew; Joshua J Jacobs; Robert M Urban
Journal:  Clin Orthop Relat Res       Date:  2017-09-07       Impact factor: 4.176

7.  Wear performance of ceramic-on-metal hip bearings.

Authors:  Jörn Reinders; Robert Sonntag; Christian Heisel; Tobias Reiner; Leo Vot; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2013-08-29       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.