Literature DB >> 20435998

The potential role of metal ion release as a marker of loosening in patients with total knee replacement: a cohort study.

L Savarino1, D Tigani, M Greco, N Baldini, A Giunti.   

Abstract

We investigated the role of ion release in the assessment of fixation of the implant after total knee replacement and hypothesised that ion monitoring could be a useful parameter in the diagnosis of prosthetic loosening. We enrolled 59 patients with unilateral procedures and measured their serum aluminium, titanium, chromium and cobalt ion levels, blinded to the clinical and radiological outcome which was considered to be the reference standard. The cut-off levels for detection of the ions were obtained by measuring the levels in 41 healthy blood donors who had no implants. Based on the clinical and radiological evaluation the patients were divided into two groups with either stable (n = 24) or loosened (n = 35) implants. A significant increase in the mean level of Cr ions was seen in the group with failed implants (p = 0.001). The diagnostic accuracy was 71% providing strong evidence of failure when the level of Cr ions exceeded the cut-off value. The possibility of distinguishing loosening from other causes of failure was demonstrated by the higher diagnostic accuracy of 83%, when considering only patients with failure attributable to loosening. Measurement of the serum level of Cr ions may be of value for detecting failure due to loosening when the diagnosis is in doubt. The other metal ions studies did not have any diagnostic value.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20435998     DOI: 10.1302/0301-620X.92B5.23452

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  4 in total

1.  Metallic ion release after knee prosthesis implantation: a prospective study.

Authors:  Adrien Lons; Sophie Putman; Gilles Pasquier; Henri Migaud; Elodie Drumez; Julien Girard
Journal:  Int Orthop       Date:  2017-06-14       Impact factor: 3.075

2.  The influence of HLA genotype on the development of metal hypersensitivity following joint replacement.

Authors:  David J Langton; Rohan M Bhalekar; Thomas J Joyce; Stephen P Rushton; Benjamin J Wainwright; Matthew E Nargol; Nish Shyam; Benedicte A Lie; Moreica B Pabbruwe; Alan J Stewart; Susan Waller; Shonali Natu; Renne Ren; Rachelle Hornick; Rebecca Darlay; Edwin P Su; Antoni V F Nargol
Journal:  Commun Med (Lond)       Date:  2022-06-24

3.  Wear in total knee arthroplasty--just a question of polyethylene?: Metal ion release in total knee arthroplasty.

Authors:  Jan Philippe Kretzer; Joern Reinders; Robert Sonntag; Sebastien Hagmann; Marcus Streit; Sebastian Jeager; Babak Moradi
Journal:  Int Orthop       Date:  2013-11-12       Impact factor: 3.075

4.  Early aseptic loosening of a mobile-bearing total knee replacement.

Authors:  Ines Kutzner; Geir Hallan; Paul Johan Høl; Ove Furnes; Øystein Gøthesen; Wender Figved; Peter Ellison
Journal:  Acta Orthop       Date:  2017-11-06       Impact factor: 3.717

  4 in total