Literature DB >> 20432362

Pulmonary kinematics from tagged hyperpolarized helium-3 MRI.

Nicholas J Tustison1, Suyash P Awate, Jing Cai, Talissa A Altes, G Wilson Miller, Eduard E de Lange, John P Mugler, James C Gee.   

Abstract

PURPOSE: To propose and test the feasibility of a novel method for quantifying 3D regional pulmonary kinematics from hyperpolarized helium-3 tagged MRI in human subjects using a tailored image processing pipeline and a recently developed nonrigid registration framework.
MATERIALS AND METHODS: Following image acquisition, inspiratory and expiratory tagged (3)He magnetic resonance (MR) images were preprocessed using various image filtering techniques to enhance the tag surfaces. Segmentation of the three orthogonal sets of tag planes in each lung produced distinct point-set representations of the tag surfaces. Using these labeled point-sets, deformation fields and corresponding strain maps were obtained via nonrigid point-set registration. Kinematic analysis was performed on three volunteers.
RESULTS: Tag lines in inspiratory and expiratory images were coregistered producing a continuous 3D correspondence mapping. Average displacement and directional strains were calculated in three subjects in the inferior, mid, and superior portions of the right and left lungs. As expected, the predominant direction of displacements with expiration is from inferior to superior.
CONCLUSION: Kinematic quantitation of pulmonary motion using tagged (3)He MRI is feasible using the applied image preprocessing filtering techniques and nonrigid point-set registration. Potential benefits from regional pulmonary kinematic quantitation include the facilitation of diagnosis and local assessment of disease progression. Copyright 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20432362      PMCID: PMC2997045          DOI: 10.1002/jmri.22137

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  15 in total

1.  MR tagging of human lungs using hyperpolarized 3He gas.

Authors:  John R Owers-Bradley; Stanislao Fichele; Abdelmalek Bennattayalah; Colin J Smith McGloin; Richard W Bowtell; Paul S Morgan; Alan R Moody
Journal:  J Magn Reson Imaging       Date:  2003-01       Impact factor: 4.813

Review 2.  Physiologic similarities and differences between asthma and chronic obstructive pulmonary disease.

Authors:  Arthur F Gelb; Noe Zamel; Anita Krishnan
Journal:  Curr Opin Pulm Med       Date:  2008-01       Impact factor: 3.155

3.  Extraction and tracking of MRI tagging sheets using a 3D Gabor filter bank.

Authors:  Zhen Qian; Dimitris N Metaxas; Leon Axel
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  A new information-theoretic measure to control the robustness-sensitivity trade-off for DMFFD point-set registration.

Authors:  Nicholas J Tustison; Suyash P Awate; Gang Song; Tessa S Cook; James C Gee
Journal:  Inf Process Med Imaging       Date:  2009

5.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

Authors:  J G Sled; A P Zijdenbos; A C Evans
Journal:  IEEE Trans Med Imaging       Date:  1998-02       Impact factor: 10.048

6.  Unsuspected loss of lung elastic recoil in chronic persistent asthma.

Authors:  Arthur F Gelb; Jesse Licuanan; Chris M Shinar; Noe Zamel
Journal:  Chest       Date:  2002-03       Impact factor: 9.410

7.  MR imaging of motion with spatial modulation of magnetization.

Authors:  L Axel; L Dougherty
Journal:  Radiology       Date:  1989-06       Impact factor: 11.105

8.  Ultrafast MR grid-tagging sequence for assessment of local mechanical properties of the lungs.

Authors:  Q Chen; V M Mai; A A Bankier; V J Napadow; R J Gilbert; R R Edelman
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

9.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.

Authors:  E A Zerhouni; D M Parish; W J Rogers; A Yang; E P Shapiro
Journal:  Radiology       Date:  1988-10       Impact factor: 11.105

10.  Dynamic MRI of grid-tagged hyperpolarized helium-3 for the assessment of lung motion during breathing.

Authors:  Jing Cai; Ke Sheng; Stanley H Benedict; Paul W Read; James M Larner; John P Mugler; Eduard E de Lange; Gordon D Cates; G Wilson Miller
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-06-18       Impact factor: 7.038

View more
  6 in total

1.  Meshless deformable models for 3D cardiac motion and strain analysis from tagged MRI.

Authors:  Xiaoxu Wang; Ting Chen; Shaoting Zhang; Joël Schaerer; Zhen Qian; Suejung Huh; Dimitris Metaxas; Leon Axel
Journal:  Magn Reson Imaging       Date:  2014-08-23       Impact factor: 2.546

2.  Internal three-dimensional strains in human intervertebral discs under axial compression quantified noninvasively by magnetic resonance imaging and image registration.

Authors:  Jonathon H Yoder; John M Peloquin; Gang Song; Nick J Tustison; Sung M Moon; Alexander C Wright; Edward J Vresilovic; James C Gee; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2014-11       Impact factor: 2.097

3.  Synchrotron-based dynamic computed tomography of tissue motion for regional lung function measurement.

Authors:  Stephen Dubsky; Stuart B Hooper; Karen K W Siu; Andreas Fouras
Journal:  J R Soc Interface       Date:  2012-04-04       Impact factor: 4.118

4.  An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation.

Authors:  Taoran Cui; G Wilson Miller; John P Mugler; Gordon D Cates; Jaime F Mata; Eduard E de Lange; Qijie Huang; Talissa A Altes; Fang-Fang Yin; Jing Cai
Journal:  Med Phys       Date:  2018-10-23       Impact factor: 4.071

5.  Regional pleural strain measurements during mechanical ventilation using ultrasound elastography: A randomized, crossover, proof of concept physiologic study.

Authors:  Martin Girard; Marie-Hélène Roy Cardinal; Michaël Chassé; Sébastien Garneau; Yiorgos Alexandros Cavayas; Guy Cloutier; André Y Denault
Journal:  Front Med (Lausanne)       Date:  2022-09-15

6.  Assessment of Pulmonary Gas Transport in Rabbits Using Hyperpolarized Xenon-129 Magnetic Resonance Imaging.

Authors:  Kai Ruppert; Hooman Hamedani; Faraz Amzajerdian; Yi Xin; Ian F Duncan; Harrilla Profka; Sarmad Siddiqui; Mehrdad Pourfathi; Stephen Kadlecek; Rahim R Rizi
Journal:  Sci Rep       Date:  2018-05-09       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.