Length of the drilling holes of zygomatic implants inserted with the standard technique or a revised method: a comparative study in dry skulls.

Paula Chiattone Corvello1, Aline Montagner, Felipe Correa Batista, Ricardo Smidt, Rosemary Sadami Shinkai.   

Abstract

AIM: This study aimed to evaluate the length of the holes drilled for the placement of zygomatic implants using two surgical techniques: the original Brånemark and the Exteriorized (extrasinus) protocols. The most frequent implant length used and position where the implants emerged in the zygomatic bone were recorded.
MATERIALS AND METHODS: Both surgical techniques for inserting zygomatic implants were performed on the right and left sides of 18 dry adult skulls. The depth of the drilling holes in the zygomatic bone for placement of zygomatic implants and the corresponding implant length were measured. The position where the implant emerged was recorded using a standardized division of the zygomatic bone surface into 13 sections (Fig. 3).
RESULTS: The Exteriorized technique showed significantly longer drilling holes for zygomatic implants than the Brånemark technique (P<0.001). For both techniques, the most commonly used implant lengths were 30 and 35 mm, and the most frequent position where the implants emerged were sections 9 and 12.
CONCLUSIONS: The results suggest that the Exteriorized technique increases the length of the drilling holes in the zygomatic bone, which may provide higher initial mechanical stability for zygomatic implants than the original Brånemark technique.
Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 20430638     DOI: 10.1016/j.jcms.2010.03.021

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  5 in total

Review 1.  Zygomatic implants: a critical review of the surgical techniques.

Authors:  Bruno Ramos Chrcanovic; Alexsander Ribeiro Pedrosa; Antônio Luís Neto Custódio
Journal:  Oral Maxillofac Surg       Date:  2012-01-25

2.  Comparative evaluation of extrasinus versus intrasinus approach for zygomatic implant placement.

Authors:  Deepika Kumari Jain; U S Pal; Shadab Mohammad; Divya Mehrotra; Ravi Katrolia; Saatvik Shandilya; Lakshya Yadav; Arunesh Kumar Tiwari
Journal:  J Oral Biol Craniofac Res       Date:  2022-09-10

3.  Evaluation of patients undergoing placement of zygomatic implants using sinus slot technique.

Authors:  P P T Araújo; S A Sousa; V B S Diniz; P P Gomes; J S P da Silva; A R Germano
Journal:  Int J Implant Dent       Date:  2016-01-13

4.  Accuracy of digital planning in zygomatic implants.

Authors:  B Xing Gao; O Iglesias-Velázquez; F G F Tresguerres; A Rodríguez González Cortes; I F Tresguerres; R Ortega Aranegui; R M López-Pintor; J López-Quiles; J Torres
Journal:  Int J Implant Dent       Date:  2021-07-22

5.  An Anatomical Study of Maxillary-Zygomatic Complex Using Three-Dimensional Computerized Tomography-Based Zygomatic Implantation.

Authors:  Xiangliang Xu; Shijie Zhao; Hui Liu; Zhipeng Sun; Jianwei Wang; Weiguang Zhang
Journal:  Biomed Res Int       Date:  2017-12-11       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.