Literature DB >> 20427973

Use of bioimpedance vector analysis in critically ill and cardiorenal patients.

W Frank Peacock Iv1.   

Abstract

Prospective outcome prediction and volume status assessment are difficult tasks in the acute care environment. Rapidly available, non-invasive, bioimpedance vector analysis (BIVA) may offer objective measures to improve clinical decision-making and predict outcomes. Performed by the placement of bipolar electrodes at the wrist and ankle, data is graphically displayed such that short-term morality risk and volume status can be accurately quantified. BIVA is able to provide indices of general cellular health, which has significant prognostic implications, as well as total body volume. Knowledge of these parameters can provide insight as to the short-term prognosis, as well as the presenting volume status. 2010 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20427973     DOI: 10.1159/000313762

Source DB:  PubMed          Journal:  Contrib Nephrol        ISSN: 0302-5144            Impact factor:   1.580


  4 in total

1.  Bioimpedance vector pattern in Taiwanese and Polish college students detected by bioelectric impedance vector analysis: preliminary observations.

Authors:  Teresa Malecka-Massalska; Agata Smolen; Elzbieta Madro; Wojciech Surtel
Journal:  ScientificWorldJournal       Date:  2012-04-19

2.  Use of Multifrequency Bioimpedance Analysis in Male Patients with Acute Kidney Injury Who Are Undergoing Continuous Veno-Venous Hemodiafiltration.

Authors:  Harin Rhee; Keum Sook Jang; Min Ji Shin; Jang Won Lee; Il Young Kim; Sang Heon Song; Dong Won Lee; Soo Bong Lee; Ihm Soo Kwak; Eun Young Seong
Journal:  PLoS One       Date:  2015-07-17       Impact factor: 3.240

3.  Bioelectrical impedance vector analysis for evaluating zinc supplementation in prepubertal and healthy children.

Authors:  Márcia Marília Gomes Dantas; Érika Dantas Medeiros Rocha; Naira Josele Neves Brito; Camila Xavier Alves; Mardone Cavalcante França; Maria das Graças Almeida; José Brandão-Neto
Journal:  Food Nutr Res       Date:  2015-09-29       Impact factor: 3.894

4.  Bioelectrical impedance vector analysis in critically ill patients: a prospective, clinician-blinded investigation.

Authors:  Sarah L Jones; Aiko Tanaka; Glenn M Eastwood; Helen Young; Leah Peck; Rinaldo Bellomo; Johan Mårtensson
Journal:  Crit Care       Date:  2015-08-12       Impact factor: 9.097

  4 in total