Literature DB >> 20426634

Validation of DynaCT in the morphological assessment of abdominal aortic aneurysm for endovascular repair.

Ian M Nordon1, Robert J Hinchliffe, Amir H Malkawi, Jeremy Taylor, Peter J Holt, Robert Morgan, Ian M Loftus, Matt M Thompson.   

Abstract

PURPOSE: To evaluate the feasibility of intraoperative 3-dimensional rotational angiography (DynaCT) as a single tool to assess suitability for endovascular aneurysm repair (EVAR) and for sizing the stent-graft.
METHODS: Twenty elective patients undergoing EVAR were prospectively recruited. All had preoperative multidetector computed tomography (CT) scans and intraoperative (pre-stent deployment) DynaCT scans. Images were read independently by 4 experienced endovascular practitioners. A total of 17 morphological variables, including aneurysm neck diameter and length, were measured from the CT and DynaCT images and compared. Bland-Altman plots examined intraclass correlation of continuous outcomes; kappa correlation coefficient assessed agreement of ordinal results.
RESULTS: The mean DynaCT radiation dose was 3751+/-835 microGym(2). The mean difference between DynaCT and multidetector CT in aneurysm neck diameter measurement was -1.5 mm (95% CI -4.9 to 1.9). Differences in left and right common iliac artery diameters were -1.9 mm (95% CI -6.3 to 2.4) and -2.1 mm (95% CI -6.9 to 2.7), respectively. For presence of neck thrombus, the group kappa statistic was 0.51 (p<0.0001); for neck calcification, the kappa was 0.07 (p = 0.29). Nine (45%) cases had incomplete information on DynaCT because external iliac arteries were not included in the scan.
CONCLUSION: DynaCT provides adequate preoperative imaging for morphological assessment of aortic anatomy. The greatest limitation is the evaluation of access vessels and underestimation of calcification. Due to current limited detector size, precise positioning is essential to attain all necessary sizing information using DynaCT.

Entities:  

Mesh:

Year:  2010        PMID: 20426634     DOI: 10.1583/09-2955.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  5 in total

1.  Flat panel catheter angiotomography of the spinal venous system: an enhanced venous phase for spinal digital subtraction angiography.

Authors:  J Chen; T Ethiati; P Gailloud
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-21       Impact factor: 3.825

2.  Percutaneous paravalvular leak closure.

Authors:  Amar Krishnaswamy; E Murat Tuzcu; Samir R Kapadia
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-10

3.  Using DynaCT for the assessment of ilio-femoral arterial calibre, calcification and tortuosity index in patients selected for trans-catheter aortic valve replacement.

Authors:  James A Crowhurst; Douglas Campbell; Owen C Raffel; Mark Whitby; Pavthrun Pathmanathan; Stanley Redmond; Alexander Incani; Karl Poon; Christopher James; Constantine Aroney; Andrew Clarke; Darren L Walters
Journal:  Int J Cardiovasc Imaging       Date:  2013-08-08       Impact factor: 2.357

4.  Novel utilization of 3D technology and the hybrid operating theatre: Peri-operative assessment of posterior sterno-clavicular dislocation using cone beam CT.

Authors:  James A Crowhurst; Douglas Campbell; Mark Whitby; Pavthrun Pathmanathan
Journal:  J Med Radiat Sci       Date:  2013-06-03

5.  Self expandable stent application to prevent limb occlusion in external iliac artery during endovascular aneurysm repair.

Authors:  Jae Hoon Lee; Ki Hyuk Park
Journal:  Ann Surg Treat Res       Date:  2016-08-29       Impact factor: 1.859

  5 in total