Literature DB >> 20425984

Nonrigid registration of myocardial perfusion MRI using pseudo ground truth.

Chao Li1, Ying Sun.   

Abstract

In this paper we present a method for nonrigid registration of myocardial perfusion MR images. Instead of registering pairs of images within the observed sequence, we register the observed sequence to a pseudo ground truth, which is a motion/noise-free sequence estimated from the observed one. As the corresponding images of the two sequences have almost identical intensity distributions, our method overcomes the challenges arising from rapidly varying image intensity and contrast. The pseudo ground truth and the deformation fields for the observed sequence are obtained simultaneously by minimizing an energy functional integrating both the registration error and the spatiotemporal constraints on the pseudo ground truth in an expectation-maximization fashion. We have tested the proposed nonrigid registration method on real cardiac MR perfusion scans, both qualitatively and quantitatively. Experimental results show that the proposed method is able to successfully compensate for the heart motion during contrast enhancement.

Mesh:

Year:  2009        PMID: 20425984     DOI: 10.1007/978-3-642-04268-3_21

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  6 in total

1.  MIA - A free and open source software for gray scale medical image analysis.

Authors:  Gert Wollny; Peter Kellman; María-Jesus Ledesma-Carbayo; Matthew M Skinner; Jean-Jaques Hublin; Thomas Hierl
Journal:  Source Code Biol Med       Date:  2013-10-11

2.  Investigation into diagnostic accuracy of common strategies for automated perfusion motion correction.

Authors:  Constantine Zakkaroff; John D Biglands; John P Greenwood; Sven Plein; Roger D Boyle; Aleksandra Radjenovic; Derek R Magee
Journal:  J Med Imaging (Bellingham)       Date:  2016-05-13

3.  Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition.

Authors:  Taehoon Shin; Krishna S Nayak; Juan M Santos; Dwight G Nishimura; Bob S Hu; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

4.  Automatic motion compensation of free breathing acquired myocardial perfusion data by using independent component analysis.

Authors:  Gert Wollny; Peter Kellman; Andrés Santos; María J Ledesma-Carbayo
Journal:  Med Image Anal       Date:  2012-02-23       Impact factor: 8.545

Review 5.  A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance.

Authors:  Merlin J Fair; Peter D Gatehouse; Edward V R DiBella; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-01       Impact factor: 5.364

6.  Patient-specific coronary blood supply territories for quantitative perfusion analysis.

Authors:  Constantine Zakkaroff; John D Biglands; John P Greenwood; Sven Plein; Roger D Boyle; Aleksandra Radjenovic; Derek R Magee
Journal:  Comput Methods Biomech Biomed Eng Imaging Vis       Date:  2016-07-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.