Literature DB >> 204238

Dual radionuclide study of acute myocardial infarction: comparison of thallium-201 and technetium-99m stannous prophosphate imaging in man.

H J Berger, A Gottschalk, B L Zaret.   

Abstract

We evaluated dual imaging with thalium-201 (201TI) and technetium-99m (99mTc) pyrophosphate in 80 patients with documented acute myocardial infarction (55 transmural, 25 nontransmural infarction). Color-coded isocount display of 201TI images was essential for interpretation in 16 patients. Combined 201 TI and 99mTc-pyrophosphate imaging for infarct detection was 100% sensitive; however, either was falsely negative in 12 of 80 patients. False-negative individual 201TI or 99mTc-pyrophosphate infarct images were most common in patients with small infacts or left ventricular hypertrophy. Thallium-201 images correctly localized the site of acute transmural infarction in all 51 patients with a positive image, while 99mTc-pyrophosphate localized the site of infarction in 49 of 53 with an abnormal image. Comparison of the size of the imaged infarct region revealed size discordance in 25 of 49 patinets, with 99mTc-pyrophosphate larger in 21 of 49 and 201TI larger in only four of 49. Thus dual radionuclide imaging provides definition of the presence and location of acute myocardial infarction.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 204238     DOI: 10.7326/0003-4819-88-2-145

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  5 in total

Review 1.  Non-invasive assessment of the effects of drugs on acute myocardial infarct size in man.

Authors:  D Maclean
Journal:  Br J Clin Pharmacol       Date:  1979-06       Impact factor: 4.335

2.  Are regions of ischaemia detected on stress perfusion scintigraphy predictive of sites of subsequent myocardial infarction?

Authors:  M Frais; E Botvinick; D Shosa; W O'Connell
Journal:  Br Heart J       Date:  1982-04

3.  Technetium-99m pyrophosphate tomogram of nontransmural myocardial infarction: a case report.

Authors:  C Kurata; K Sakata; T Taguchi; A Kobayashi; N Yamazaki
Journal:  Ann Nucl Med       Date:  1988-11       Impact factor: 2.668

4.  Thallium 201 scintigraphy.

Authors:  J H McKillop
Journal:  West J Med       Date:  1980-07

5.  Comparative Cardiac Phantom Study Using Tc-99m/I-123 and Tl-201/I-123 Tracers with Cadmium-Zinc-Telluride Detector-Based Single-Photon Emission Computed Tomography.

Authors:  Takanaga Niimi; Mamoru Nanasato; Mitsuo Sugimoto; Hisatoshi Maeda
Journal:  Nucl Med Mol Imaging       Date:  2018-12-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.