Literature DB >> 20420958

Cervical spine mobilisation forces applied by physiotherapy students.

Suzanne J Snodgrass1, Darren A Rivett, Val J Robertson, Elizabeth Stojanovski.   

Abstract

OBJECTIVES: Postero-anterior (PA) mobilisation is commonly used in cervical spine treatment and included in physiotherapy curricula. The manual forces that students apply while learning cervical mobilisation are not known. Quantifying these forces informs the development of strategies for learning to apply cervical mobilisation effectively and safely. This study describes the mechanical properties of cervical PA mobilisation techniques applied by students, and investigates factors associated with force application. PARTICIPANTS: Physiotherapy students (n=120) mobilised one of 32 asymptomatic subjects.
METHODS: Students applied Grades I to IV central and unilateral PA mobilisation to C2 and C7 of one asymptomatic subject. Manual forces were measured in three directions using an instrumented treatment table. Spinal stiffness of mobilised subjects was measured at C2 and C7 using a device that applied a standard oscillating force while measuring this force and its concurrent displacement. Analysis of variance was used to determine differences between techniques and grades, intraclass correlation coefficients (ICC) were used to calculate the inter- and intrastudent repeatability of forces, and linear regression was used to determine the associations between applied forces and characteristics of students and mobilised subjects.
RESULTS: Mobilisation forces increased from Grades I to IV (highest mean peak force, Grade IV C7 central PA technique: 63.7N). Interstudent reliability was poor [ICC(2,1)=0.23, 95% confidence interval (CI) 0.14 to 0.43], but intrastudent repeatability of forces was somewhat better (0.83, 95% CI 0.81 to 0.86). Higher applied force was associated with greater C7 stiffness, increased frequency of thumb pain, male gender of the student or mobilised subject, and a student being earlier in their learning process. Lower forces were associated with greater C2 stiffness.
CONCLUSION: This study describes the cervical mobilisation forces applied by students, and the characteristics of the student and mobilised subject associated with these forces. These results form a basis for the development of strategies to provide objective feedback to students learning to apply cervical mobilisation. Copyright 2009 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 20420958     DOI: 10.1016/j.physio.2009.08.008

Source DB:  PubMed          Journal:  Physiotherapy        ISSN: 0031-9406            Impact factor:   3.358


  9 in total

1.  Knowledge transfer of spinal manipulation skills by student-teachers: a randomised controlled trial.

Authors:  Matthias Knobe; Malte Holschen; Saskia Catharina Mooij; Richard Martin Sellei; Ralf Münker; Pia Antony; Roman Pfeifer; Wolf Drescher; Hans-Christoph Pape
Journal:  Eur Spine J       Date:  2012-01-06       Impact factor: 3.134

2.  Biomechanical measures of knee joint mobilization.

Authors:  Jason L Silvernail; Norman W Gill; Deydre S Teyhen; Stephen C Allison
Journal:  J Man Manip Ther       Date:  2011-08

3.  Training and certification of doctors of chiropractic in delivering manual cervical traction forces: Results of a longitudinal observational study.

Authors:  Maruti Ram Gudavalli; Robert D Vining; Stacie A Salsbury; Christine M Goertz
Journal:  J Chiropr Educ       Date:  2014-09-19

4.  Real-time force feedback during flexion-distraction procedure for low back pain: A pilot study.

Authors:  Maruti Ram Gudavalli; James M Cox
Journal:  J Can Chiropr Assoc       Date:  2014-06

5.  Clinician proficiency in delivering manual treatment for neck pain within specified force ranges.

Authors:  Maruti Ram Gudavalli; Robert D Vining; Stacie A Salsbury; Lance G Corber; Cynthia R Long; Avinash G Patwardhan; Christine M Goertz
Journal:  Spine J       Date:  2014-10-22       Impact factor: 4.166

6.  A simulated passive intervertebral motion task: observations of performance in a cross-sectional study.

Authors:  Charles R Hazle; Arthur J Nitz
Journal:  J Man Manip Ther       Date:  2012-08

7.  Intraclinician Variability in Force Application During Anteroposterior Mobilization of the Ankle Joint.

Authors:  Aaron J Wholohan; Ted Jedynak
Journal:  J Chiropr Med       Date:  2022-04-04

Review 8.  Devices Used to Measure Force-Time Characteristics of Spinal Manipulations and Mobilizations: A Mixed-Methods Scoping Review on Metrologic Properties and Factors Influencing Use.

Authors:  Marie-Andrée Mercier; Philippe Rousseau; Martha Funabashi; Martin Descarreaux; Isabelle Pagé
Journal:  Front Pain Res (Lausanne)       Date:  2021-10-29

9.  Inertial sensor real-time feedback enhances the learning of cervical spine manipulation: a prospective study.

Authors:  Antonio I Cuesta-Vargas; Jonathan Williams
Journal:  BMC Med Educ       Date:  2014-06-19       Impact factor: 2.463

  9 in total