Literature DB >> 20417567

Randomized, sham-controlled trial of dexamethasone intravitreal implant in patients with macular edema due to retinal vein occlusion.

Julia A Haller1, Francesco Bandello, Rubens Belfort, Mark S Blumenkranz, Mark Gillies, Jeffrey Heier, Anat Loewenstein, Young-Hee Yoon, Marie-Louise Jacques, Jenny Jiao, Xiao-Yan Li, Scott M Whitcup.   

Abstract

OBJECTIVE: To evaluate the safety and efficacy of dexamethasone intravitreal implant (DEX implant; OZURDEX, Allergan, Inc., Irvine, CA) compared with sham in eyes with vision loss due to macular edema (ME) associated with branch retinal vein occlusion (BRVO) or central retinal vein occlusion (CRVO).
DESIGN: Two identical, multicenter, masked, randomized, 6-month, sham-controlled clinical trials (each of which included patients with BRVO and patients with CRVO). PARTICIPANTS: A total of 1267 patients with vision loss due to ME associated with BRVO or CRVO. INTERVENTION: A single treatment with DEX implant 0.7 mg (n = 427), DEX implant 0.35 mg (n = 414), or sham (n = 426). MAIN OUTCOME MEASURES: The primary outcome measure for the pooled data from the 2 studies was time to achieve a > or =15-letter improvement in best-corrected visual acuity (BCVA). Secondary end points included BCVA, central retinal thickness, and safety.
RESULTS: After a single administration, the time to achieve a > or =15-letter improvement in BCVA was significantly less in both DEX implant groups compared with sham (P<0.001). The percentage of eyes with a > or =15-letter improvement in BCVA was significantly higher in both DEX implant groups compared with sham at days 30 to 90 (P<0.001). The percentage of eyes with a > or =15-letter loss in BCVA was significantly lower in the DEX implant 0.7-mg group compared with sham at all follow-up visits (P< or =0.036). Improvement in mean BCVA was greater in both DEX implant groups compared with sham at all follow-up visits (P< or =0.006). Improvements in BCVA with DEX implant were seen in patients with BRVO and patients with CRVO, although the patterns of response differed. The percentage of DEX implant-treated eyes with intraocular pressure (IOP) of > or =25 mmHg peaked at 16% at day 60 (both doses) and was not different from sham by day 180. There was no significant between-group difference in the occurrence of cataract or cataract surgery.
CONCLUSIONS: Dexamethasone intravitreal implant can both reduce the risk of vision loss and improve the speed and incidence of visual improvement in eyes with ME secondary to BRVO or CRVO and may be a useful therapeutic option for eyes with these conditions. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20417567     DOI: 10.1016/j.ophtha.2010.03.032

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  286 in total

Review 1.  Anti-vascular endothelial growth factor for macular edema secondary to central retinal vein occlusion.

Authors:  Tasanee Braithwaite; Afshan A Nanji; Paul B Greenberg
Journal:  Cochrane Database Syst Rev       Date:  2010-10-06

2.  Steroid implant in anterior chamber of an aphakic vitrectomized eye.

Authors:  Jost B Jonas; Matthias Schmidbauer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-10-18       Impact factor: 3.117

Review 3.  Emerging therapeutic approaches in the management of retinal angiogenesis and edema.

Authors:  An Truong; Tien Y Wong; Levon M Khachigian
Journal:  J Mol Med (Berl)       Date:  2010-12-18       Impact factor: 4.599

Review 4.  Central retinal vein occlusion: modifying current treatment protocols.

Authors:  M Ashraf; A A R Souka; R P Singh
Journal:  Eye (Lond)       Date:  2016-02-12       Impact factor: 3.775

Review 5.  [Intravitreal implants: drug carriers and carriers of hope?].

Authors:  S Winterhalter; P Ruokonen; K H van der Velden; U Pleyer; A M Joussen
Journal:  Ophthalmologe       Date:  2011-03       Impact factor: 1.059

6.  Comparison between ranibizumab and aflibercept for macular edema associated with central retinal vein occlusion.

Authors:  Yoshitsugu Saishin; Yuka Ito; Masato Fujikawa; Tomoko Sawada; Masahito Ohji
Journal:  Jpn J Ophthalmol       Date:  2016-09-22       Impact factor: 2.447

Review 7.  The therapeutic potential of intraocular depot steroid systems: developments aimed at prolonging duration of efficacy.

Authors:  Martin M Nentwich; Michael W Ulbig
Journal:  Dtsch Arztebl Int       Date:  2012-09-14       Impact factor: 5.594

8.  Effect of posterior sub-tenon triamcinolone in macular edema due to non-ischemic vein occlusions.

Authors:  Murali Mohan Gurram
Journal:  J Clin Diagn Res       Date:  2013-09-13

9.  Anti-VEGF versus dexamethasone implant (Ozurdex) for the management of Centre involved Diabetic Macular Edema (CiDME): a randomized study.

Authors:  Ashish Sharma; Keerthi Bellala; Pankaj Dongre; Prahalad Reddy
Journal:  Int Ophthalmol       Date:  2019-08-03       Impact factor: 2.031

10.  Current treatments in diabetic macular oedema: systematic review and meta-analysis.

Authors:  John Alexander Ford; Noemi Lois; Pamela Royle; Christine Clar; Deepson Shyangdan; Norman Waugh
Journal:  BMJ Open       Date:  2013-03-01       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.