Literature DB >> 20416525

Cutting efficiency of 3 different instrument designs used in reciprocation.

Jeffrey Wan1, Brian J Rasimick, Barry L Musikant, Allan S Deutsch.   

Abstract

OBJECTIVE: This study examined the effect of flute number and cross-sectional area on the cutting efficiency of 3 reciprocating endodontic instruments twisted from rectangular stainless steel wire; 40/0.02 instruments at 25-mm length were compared. STUDY
DESIGN: Seventy-five anterior teeth were prepared, divided into 3 groups, and operated on with a reciprocating handpiece at 2500 rpm for 5 seconds at around 500 grams of force: Group 1, SafeSiders; Group 2, Dentsply K-Files; Group 3, Dentsply K-Reamers. Dentin generated was collected in weigh dishes. Cutting efficiency was determined by dentin weight. Statistical analysis was performed with 1-way ANOVA and the Student-Neuman-Keuls (SNK) multiple comparisons testing.
RESULTS: SafeSider instruments produced a greater amount of debris than K-Files and K-Reamers (P < .026). K-Files and K-Reamers were not statistically different (P = .63).
CONCLUSIONS: Flute number had no effect on cutting efficiency. Cross-sectional area may be a determining factor on cutting efficiency. Copyright (c) 2010 Mosby, Inc. All rights reserved.

Mesh:

Substances:

Year:  2010        PMID: 20416525     DOI: 10.1016/j.tripleo.2009.12.037

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  6 in total

1.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

2.  Cutting efficiency of four different rotary nickel: Titanium instruments.

Authors:  Doglas Cecchin; Manoel Damião de Sousa-Neto; Jesus Djalma Pécora; Ricardo Gariba-Silva
Journal:  J Conserv Dent       Date:  2011-04

3.  Cutting efficiency of instruments with different movements: a comparative study.

Authors:  Luigi Tocci; Gianluca Plotino; Dina Al-Sudani; Alessio Giansiracusa Rubini; Gianpaolo Sannino; Lucila Piasecki; Ermanno Putortì; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2015-03-30

4.  A new device to test cutting efficiency of mechanical endodontic instruments.

Authors:  Alessio Giansiracusa Rubini; Gianluca Plotino; Dina Al-Sudani; Nicola M Grande; Gianpaolo Sonnino; Ermanno Putorti; Elisabetta Cotti; Luca Testarelli; Gianluca Gambarini
Journal:  Med Sci Monit       Date:  2014-03-06

5.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

6.  Influence of heat treatment on cyclic fatigue and cutting efficiency of ProTaper Universal F2 instruments.

Authors:  Chih-Wen Chi; Eddie Hsiang-Hua Lai; Chao-Yuan Liu; Chun-Pin Lin; Chow-Shing Shin
Journal:  J Dent Sci       Date:  2016-08-10       Impact factor: 2.080

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.