Literature DB >> 20409232

How can we safely use ultrasonic laparoscopic coagulating shears?

Jae Sik Kim1, Ryohei Hattori, Tokunori Yamamoto, Yasushi Yoshino, Momokazu Gotoh.   

Abstract

PURPOSE: To investigate changes in temperature of the tissue pad (contrary to active blade) of ultrasonic laparoscopic coagulation shears (LCS) and histological changes of tissue surrounding the pad during activation.
METHODS: Three types of ultrasonic LCS were assessed: SonoSurg (SSg) (Olympus, Tokyo, Japan), AutoSonix (AS) (Tyco, Pembroke, Bermuda) and Harmonic Scalpel (HS) (Johnson & Johnson, Cincinnati, OH, USA). Vibration amplitudes were 70%/100% (SSg), Level 3/Level 5 (AS) and Level 5 (HS). Durations of vibration were 5 s, 10 s, 15 s and 20 s. Changes in temperature of the tissue pad were evaluated by cutting chicken parts extracorporeally with the three types of LCS. Histological changes around the tissue pad of the SSg were evaluated in a laparoscopic porcine model.
RESULTS: At intermediate power (70% or Level 3), the SSg tissue pad temperatures were 33 degrees C, 42 degrees C, 55 degrees C and 70 degrees C, whereas the AS tissue pad temperatures were 45 degrees C, 72 degrees C, 80 degrees C and 100 degrees C. At maximum power, the temperatures of the SSg tissue pad were 38 degrees C, 45 degrees C, 70 degrees C and 95 degrees C, those of the AS were 50 degrees C, 65 degrees C, 70 degrees C and 90 degrees C and those of the HS were 49 degrees C, 65 degrees C, 75 degrees C and 90 degrees C. Histological changes occurred at 10 s, 15 s and 20 s.
CONCLUSION: Surgeons should be aware that the temperature of the tissue pad also becomes elevated when using ultrasonic LCS. Thus, they should be concerned with surrounding tissues and organs around both the tissue pad and the active blade during activation. Regardless of the LCS type and power, a short activation time within 5 s is a safe method for using the instrument.

Entities:  

Mesh:

Year:  2010        PMID: 20409232     DOI: 10.1111/j.1442-2042.2010.02506.x

Source DB:  PubMed          Journal:  Int J Urol        ISSN: 0919-8172            Impact factor:   3.369


  5 in total

Review 1.  [Intraoperative complications of the lower gastrointestinal tract : Prevention, recognition and therapy].

Authors:  J-P Ritz
Journal:  Chirurg       Date:  2015-04       Impact factor: 0.955

Review 2.  Common uses and cited complications of energy in surgery.

Authors:  Ganesh Sankaranarayanan; Rajeswara R Resapu; Daniel B Jones; Steven Schwaitzberg; Suvranu De
Journal:  Surg Endosc       Date:  2013-04-23       Impact factor: 4.584

3.  Intestinal Injury by Heat Conduction from Surgical Sealing Devices.

Authors:  Toshiro Suzuki; Ryouhei Hattori; Tomonori Minagawa; Takeshi Uehara; Teruyuki Ogawa; Osamu Ishizuka
Journal:  JSLS       Date:  2019 Jan-Mar       Impact factor: 2.172

4.  Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade.

Authors:  Saverio Latteri; Giuseppe Stella; Anna M Gueli; Stefania Mazzaglia; Valentina Palumbo; Tommaso Guastella
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2019-10       Impact factor: 1.719

5.  Is endourological intervention a suitable treatment option in the management of iatrogenic thermal ureteral injury? A contemporary case series.

Authors:  Oğuz Özden Cebeci
Journal:  BMC Urol       Date:  2022-09-03       Impact factor: 2.090